Network Configuration: Difference between revisions
No edit summary |
No edit summary |
||
(9 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
[[Category:Reference Documentation]] | [[Category:Reference Documentation]] | ||
<pvehide> | <pvehide> | ||
Proxmox VE is using the Linux network stack. This provides a lot of flexibility on | |||
editing the file /etc/network/interfaces, which contains the | how to set up the network on the Proxmox VE nodes. The configuration can be done | ||
whole network configuration. The interfaces(5) manual page contains the | either via the GUI, or by manually editing the file /etc/network/interfaces, | ||
complete format description. All Proxmox VE tools try hard to keep direct | which contains the whole network configuration. The interfaces(5) manual | ||
user modifications, but using the GUI is still preferable, because it | page contains the complete format description. All Proxmox VE tools try hard to keep | ||
direct user modifications, but using the GUI is still preferable, because it | |||
protects you from errors. | protects you from errors. | ||
A vmbr interface is needed to connect guests to the underlying physical | |||
network. They are a Linux bridge which can be thought of as a virtual switch | |||
to which the guests and physical interfaces are connected to. This section | |||
provides some examples on how the network can be set up to accomodate different | |||
use cases like redundancy with a bond, | |||
vlans or | |||
routed and | |||
NAT setups. | |||
The Software Defined Network is an option for more complex | |||
virtual networks in Proxmox VE clusters. | |||
It’s discouraged to use the traditional Debian tools ifup and ifdown | |||
if unsure, as they have some pitfalls like interupting all guest traffic on | |||
ifdown vmbrX but not reconnecting those guest again when doing ifup on the | |||
same bridge later. | |||
Apply Network Changes | Apply Network Changes | ||
Proxmox VE does not write changes directly to /etc/network/interfaces. Instead, we | Proxmox VE does not write changes directly to /etc/network/interfaces. Instead, we | ||
Line 18: | Line 31: | ||
are correct before applying, as a wrong network configuration may render a node | are correct before applying, as a wrong network configuration may render a node | ||
inaccessible. | inaccessible. | ||
Live-Reload Network with ifupdown2 | |||
With the recommended ifupdown2 package (default for new installations since | |||
Proxmox VE 7.0), it is possible to apply network configuration changes without a | |||
reboot. If you change the network configuration via the GUI, you can click the | |||
Apply Configuration button. This will move changes from the staging | |||
Reload Network with ifupdown2 | interfaces.new file to /etc/network/interfaces and apply them live. | ||
With the | If you made manual changes directly to the /etc/network/interfaces file, you | ||
network configuration | can apply them by running ifreload -a | ||
If you installed Proxmox VE on top of Debian, or upgraded to Proxmox VE 7.0 from an | |||
older Proxmox VE installation, make sure ifupdown2 is installed: apt install | |||
ifupdown2 | |||
Reboot Node to Apply | |||
Another way to apply a new network configuration is to reboot the node. | |||
In that case the systemd service pvenetcommit will activate the staging | |||
interfaces.new file before the networking service will apply that | |||
configuration. | |||
apt install ifupdown2 | |||
Naming Conventions | Naming Conventions | ||
We currently use the following naming conventions for device names: | We currently use the following naming conventions for device names: | ||
Line 54: | Line 61: | ||
name implies the device type. | name implies the device type. | ||
Systemd Network Interface Names | Systemd Network Interface Names | ||
Systemd uses the two character prefix en for Ethernet network | Systemd defines a versioned naming scheme for network device names. The | ||
devices. The next characters depends on the device driver and | scheme uses the two-character prefix en for Ethernet network devices. The | ||
next characters depends on the device driver, device location and other | |||
attributes. Some possible patterns are: | |||
o<index>[n<phys_port_name>|d<dev_port>] â devices on board | o<index>[n<phys_port_name>|d<dev_port>] â devices on board | ||
s<slot>[f<function>][n<phys_port_name>|d<dev_port>] â | s<slot>[f<function>][n<phys_port_name>|d<dev_port>] â devices by hotplug id | ||
[P<domain>]p<bus>s<slot>[f<function>][n<phys_port_name>|d<dev_port>] â devices by bus id | [P<domain>]p<bus>s<slot>[f<function>][n<phys_port_name>|d<dev_port>] â | ||
x<MAC> â | devices by bus id | ||
x<MAC> â devices by MAC address | |||
eno1 â is the first on board NIC | Some examples for the most common patterns are: | ||
enp3s0f1 â is the NIC on | eno1 â is the first on-board NIC | ||
For more information see Predictable Network Interface Names. | enp3s0f1 â is function 1 of the NIC on PCI bus 3, slot 0 | ||
For a full list of possible device name patterns, see the | |||
systemd.net-naming-scheme(7) manpage. | |||
A new version of systemd may define a new version of the network device naming | |||
scheme, which it then uses by default. Consequently, updating to a newer | |||
systemd version, for example during a major Proxmox VE upgrade, can change the names | |||
of network devices and require adjusting the network configuration. To avoid | |||
name changes due to a new version of the naming scheme, you can manually pin a | |||
particular naming scheme version (see | |||
below). | |||
However, even with a pinned naming scheme version, network device names can | |||
still change due to kernel or driver updates. In order to avoid name changes | |||
for a particular network device altogether, you can manually override its name | |||
using a link file (see below). | |||
For more information on network interface names, see | |||
Predictable Network Interface | |||
Names. | |||
Pinning a specific naming scheme version | |||
You can pin a specific version of the naming scheme for network devices by | |||
adding the net.naming-scheme=<version> parameter to the | |||
kernel command line. For a list of naming | |||
scheme versions, see the | |||
systemd.net-naming-scheme(7) manpage. | |||
For example, to pin the version v252, which is the latest naming scheme | |||
version for a fresh Proxmox VE 8.0 installation, add the following kernel | |||
command-line parameter: | |||
net.naming-scheme=v252 | |||
See also this section on editing the kernel | |||
command line. You need to reboot for the changes to take effect. | |||
Overriding network device names | |||
You can manually assign a name to a particular network device using a custom | |||
systemd.link | |||
file. This overrides the name that would be assigned according to the latest | |||
network device naming scheme. This way, you can avoid naming changes due to | |||
kernel updates, driver updates or newer versions of the naming scheme. | |||
Custom link files should be placed in /etc/systemd/network/ and named | |||
<n>-<id>.link, where n is a priority smaller than 99 and id is some | |||
identifier. A link file has two sections: [Match] determines which interfaces | |||
the file will apply to; [Link] determines how these interfaces should be | |||
configured, including their naming. | |||
To assign a name to a particular network device, you need a way to uniquely and | |||
permanently identify that device in the [Match] section. One possibility is | |||
to match the device’s MAC address using the MACAddress option, as it is | |||
unlikely to change. Then, you can assign a name using the Name option in the | |||
[Link] section. | |||
For example, to assign the name enwan0 to the device with MAC address | |||
aa:bb:cc:dd:ee:ff, create a file /etc/systemd/network/10-enwan0.link with | |||
the following contents: | |||
[Match] | |||
MACAddress=aa:bb:cc:dd:ee:ff | |||
[Link] | |||
Name=enwan0 | |||
Do not forget to adjust /etc/network/interfaces to use the new name. | |||
You need to reboot the node for the change to take effect. | |||
It is recommended to assign a name starting with en or eth so that | |||
Proxmox VE recognizes the interface as a physical network device which can then be | |||
configured via the GUI. Also, you should ensure that the name will not clash | |||
with other interface names in the future. One possibility is to assign a name | |||
that does not match any name pattern that systemd uses for network interfaces | |||
(see above), such as enwan0 in the | |||
example above. | |||
For more information on link files, see the | |||
systemd.link(5) | |||
manpage. | |||
Choosing a network configuration | Choosing a network configuration | ||
Depending on your current network organization and your resources you can | Depending on your current network organization and your resources you can | ||
Line 98: | Line 169: | ||
auto vmbr0 | auto vmbr0 | ||
iface vmbr0 inet static | iface vmbr0 inet static | ||
address 192.168.10.2 | address 192.168.10.2/24 | ||
gateway 192.168.10.1 | gateway 192.168.10.1 | ||
bridge-ports eno1 | |||
bridge-stp off | |||
bridge-fd 0 | |||
Virtual machines behave as if they were directly connected to the | Virtual machines behave as if they were directly connected to the | ||
physical network. The network, in turn, sees each virtual machine as | physical network. The network, in turn, sees each virtual machine as | ||
Line 112: | Line 182: | ||
reasons, they disable networking as soon as they detect multiple MAC | reasons, they disable networking as soon as they detect multiple MAC | ||
addresses on a single interface. | addresses on a single interface. | ||
Some providers | Some providers allow you to register additional MACs through their | ||
management interface. This avoids the problem, but | management interface. This avoids the problem, but can be clumsy to | ||
configure because you need to register a MAC for each of your VMs. | configure because you need to register a MAC for each of your VMs. | ||
You can avoid the problem by “routing” all traffic via a single | You can avoid the problem by “routing” all traffic via a single | ||
Line 120: | Line 190: | ||
A common scenario is that you have a public IP (assume 198.51.100.5 | A common scenario is that you have a public IP (assume 198.51.100.5 | ||
for this example), and an additional IP block for your VMs | for this example), and an additional IP block for your VMs | ||
(203.0.113.16/ | (203.0.113.16/28). We recommend the following setup for such | ||
situations: | situations: | ||
auto lo | auto lo | ||
iface lo inet loopback | iface lo inet loopback | ||
auto | auto eno0 | ||
iface | iface eno0 inet static | ||
address 198.51.100.5 | address 198.51.100.5/29 | ||
gateway 198.51.100.1 | gateway 198.51.100.1 | ||
post-up echo 1 > /proc/sys/net/ipv4/ip_forward | post-up echo 1 > /proc/sys/net/ipv4/ip_forward | ||
post-up echo 1 > /proc/sys/net/ipv4/conf/ | post-up echo 1 > /proc/sys/net/ipv4/conf/eno0/proxy_arp | ||
auto vmbr0 | auto vmbr0 | ||
iface vmbr0 inet static | iface vmbr0 inet static | ||
address 203.0.113.17 | address 203.0.113.17/28 | ||
bridge-ports none | |||
bridge-stp off | |||
bridge-fd 0 | |||
Masquerading (NAT) with iptables | Masquerading (NAT) with iptables | ||
Masquerading allows guests having only a private IP address to access the | Masquerading allows guests having only a private IP address to access the | ||
Line 148: | Line 216: | ||
#real IP address | #real IP address | ||
iface eno1 inet static | iface eno1 inet static | ||
address 198.51.100.5 | address 198.51.100.5/24 | ||
gateway 198.51.100.1 | gateway 198.51.100.1 | ||
auto vmbr0 | auto vmbr0 | ||
#private sub network | #private sub network | ||
iface vmbr0 inet static | iface vmbr0 inet static | ||
address 10.10.10.1 | address 10.10.10.1/24 | ||
bridge-ports none | |||
bridge-stp off | |||
bridge-fd 0 | |||
post-up echo 1 > /proc/sys/net/ipv4/ip_forward | post-up echo 1 > /proc/sys/net/ipv4/ip_forward | ||
post-up iptables -t nat -A POSTROUTING -s '10.10.10.0/24' -o eno1 -j MASQUERADE | post-up iptables -t nat -A POSTROUTING -s '10.10.10.0/24' -o eno1 -j MASQUERADE | ||
Line 227: | Line 293: | ||
the corresponding bonding mode (802.3ad). Otherwise you should generally use the | the corresponding bonding mode (802.3ad). Otherwise you should generally use the | ||
active-backup mode. | active-backup mode. | ||
For the cluster network (Corosync) we recommend configuring it with multiple | |||
networks. Corosync does not need a bond for network reduncancy as it can switch | |||
between networks by itself, if one becomes unusable. | |||
The following bond configuration can be used as distributed/shared | The following bond configuration can be used as distributed/shared | ||
storage network. The benefit would be that you get more speed and the | storage network. The benefit would be that you get more speed and the | ||
Line 238: | Line 304: | ||
iface eno1 inet manual | iface eno1 inet manual | ||
iface eno2 inet manual | iface eno2 inet manual | ||
iface eno3 inet manual | |||
auto bond0 | auto bond0 | ||
iface bond0 inet static | iface bond0 inet static | ||
slaves eno1 eno2 | bond-slaves eno1 eno2 | ||
address 192.168.1.2 | address 192.168.1.2/24 | ||
bond-miimon 100 | |||
bond-mode 802.3ad | |||
bond-xmit-hash-policy layer2+3 | |||
auto vmbr0 | auto vmbr0 | ||
iface vmbr0 inet static | iface vmbr0 inet static | ||
address 10.10.10.2 | address 10.10.10.2/24 | ||
gateway 10.10.10.1 | gateway 10.10.10.1 | ||
bridge-ports eno3 | |||
bridge-stp off | |||
bridge-fd 0 | |||
Another possibility it to use the bond directly as bridge port. | Another possibility it to use the bond directly as bridge port. | ||
This can be used to make the guest network fault-tolerant. | This can be used to make the guest network fault-tolerant. | ||
Line 263: | Line 328: | ||
auto bond0 | auto bond0 | ||
iface bond0 inet manual | iface bond0 inet manual | ||
slaves eno1 eno2 | bond-slaves eno1 eno2 | ||
bond-miimon 100 | |||
bond-mode 802.3ad | |||
bond-xmit-hash-policy layer2+3 | |||
auto vmbr0 | auto vmbr0 | ||
iface vmbr0 inet static | iface vmbr0 inet static | ||
address 10.10.10.2 | address 10.10.10.2/24 | ||
gateway 10.10.10.1 | gateway 10.10.10.1 | ||
bridge-ports bond0 | |||
bridge-stp off | |||
bridge-fd 0 | |||
VLAN 802.1Q | VLAN 802.1Q | ||
A virtual LAN (VLAN) is a broadcast domain that is partitioned and | A virtual LAN (VLAN) is a broadcast domain that is partitioned and | ||
Line 319: | Line 383: | ||
auto vmbr0v5 | auto vmbr0v5 | ||
iface vmbr0v5 inet static | iface vmbr0v5 inet static | ||
address 10.10.10.2 | address 10.10.10.2/24 | ||
gateway 10.10.10.1 | gateway 10.10.10.1 | ||
bridge-ports eno1.5 | |||
bridge-stp off | |||
bridge-fd 0 | |||
auto vmbr0 | auto vmbr0 | ||
iface vmbr0 inet manual | iface vmbr0 inet manual | ||
bridge-ports eno1 | |||
bridge-stp off | |||
bridge-fd 0 | |||
Example: Use VLAN 5 for the Proxmox VE management IP with VLAN aware Linux bridge | Example: Use VLAN 5 for the Proxmox VE management IP with VLAN aware Linux bridge | ||
auto lo | auto lo | ||
Line 336: | Line 399: | ||
auto vmbr0.5 | auto vmbr0.5 | ||
iface vmbr0.5 inet static | iface vmbr0.5 inet static | ||
address 10.10.10.2 | address 10.10.10.2/24 | ||
gateway 10.10.10.1 | gateway 10.10.10.1 | ||
auto vmbr0 | auto vmbr0 | ||
iface vmbr0 inet manual | iface vmbr0 inet manual | ||
bridge-ports eno1 | |||
bridge-stp off | |||
bridge-fd 0 | |||
bridge-vlan-aware yes | |||
bridge-vids 2-4094 | |||
The next example is the same setup but a bond is used to | The next example is the same setup but a bond is used to | ||
make this network fail-safe. | make this network fail-safe. | ||
Line 354: | Line 417: | ||
auto bond0 | auto bond0 | ||
iface bond0 inet manual | iface bond0 inet manual | ||
slaves eno1 eno2 | bond-slaves eno1 eno2 | ||
bond-miimon 100 | |||
bond-mode 802.3ad | |||
bond-xmit-hash-policy layer2+3 | |||
iface bond0.5 inet manual | iface bond0.5 inet manual | ||
auto vmbr0v5 | auto vmbr0v5 | ||
iface vmbr0v5 inet static | iface vmbr0v5 inet static | ||
address 10.10.10.2 | address 10.10.10.2/24 | ||
gateway 10.10.10.1 | gateway 10.10.10.1 | ||
bridge-ports bond0.5 | |||
bridge-stp off | |||
bridge-fd 0 | |||
auto vmbr0 | auto vmbr0 | ||
iface vmbr0 inet manual | iface vmbr0 inet manual | ||
bridge-ports bond0 | |||
bridge-stp off | |||
bridge-fd 0 | |||
Disabling IPv6 on the Node | |||
Proxmox VE works correctly in all environments, irrespective of whether IPv6 is | |||
deployed or not. We recommend leaving all settings at the provided defaults. | |||
Should you still need to disable support for IPv6 on your node, do so by | |||
creating an appropriate sysctl.conf (5) snippet file and setting the proper | |||
sysctls, | |||
for example adding /etc/sysctl.d/disable-ipv6.conf with content: | |||
net.ipv6.conf.all.disable_ipv6 = 1 | |||
net.ipv6.conf.default.disable_ipv6 = 1 | |||
This method is preferred to disabling the loading of the IPv6 module on the | |||
kernel commandline. | |||
Disabling MAC Learning on a Bridge | |||
By default, MAC learning is enabled on a bridge to ensure a smooth experience | |||
with virtual guests and their networks. | |||
But in some environments this can be undesired. Since Proxmox VE 7.3 you can disable | |||
MAC learning on the bridge by setting the ‘bridge-disable-mac-learning 1` | |||
configuration on a bridge in `/etc/network/interfaces’, for example: | |||
# ... | |||
auto vmbr0 | |||
iface vmbr0 inet static | |||
address 10.10.10.2/24 | |||
gateway 10.10.10.1 | |||
bridge-ports ens18 | |||
bridge-stp off | |||
bridge-fd 0 | |||
bridge-disable-mac-learning 1 | |||
Once enabled, Proxmox VE will manually add the configured MAC address from VMs and | |||
Containers to the bridges forwarding database to ensure that guest can still | |||
use the network - but only when they are using their actual MAC address. | |||
</pvehide> | </pvehide> | ||
<!--PVE_IMPORT_END_MARKER--> | <!--PVE_IMPORT_END_MARKER--> |
Latest revision as of 14:11, 23 November 2023
Proxmox VE is using the Linux network stack. This provides a lot of flexibility on how to set up the network on the Proxmox VE nodes. The configuration can be done either via the GUI, or by manually editing the file /etc/network/interfaces, which contains the whole network configuration. The interfaces(5) manual page contains the complete format description. All Proxmox VE tools try hard to keep direct user modifications, but using the GUI is still preferable, because it protects you from errors.
A Linux bridge interface (commonly called vmbrX) is needed to connect guests to the underlying physical network. It can be thought of as a virtual switch which the guests and physical interfaces are connected to. This section provides some examples on how the network can be set up to accommodate different use cases like redundancy with a bond, vlans or routed and NAT setups.
The Software Defined Network is an option for more complex virtual networks in Proxmox VE clusters.
It’s discouraged to use the traditional Debian tools ifup and ifdown if unsure, as they have some pitfalls like interrupting all guest traffic on ifdown vmbrX but not reconnecting those guest again when doing ifup on the same bridge later. |
Apply Network Changes
Proxmox VE does not write changes directly to /etc/network/interfaces. Instead, we write into a temporary file called /etc/network/interfaces.new, this way you can do many related changes at once. This also allows to ensure your changes are correct before applying, as a wrong network configuration may render a node inaccessible.
Live-Reload Network with ifupdown2
With the recommended ifupdown2 package (default for new installations since Proxmox VE 7.0), it is possible to apply network configuration changes without a reboot. If you change the network configuration via the GUI, you can click the Apply Configuration button. This will move changes from the staging interfaces.new file to /etc/network/interfaces and apply them live.
If you made manual changes directly to the /etc/network/interfaces file, you can apply them by running ifreload -a
If you installed Proxmox VE on top of Debian, or upgraded to Proxmox VE 7.0 from an older Proxmox VE installation, make sure ifupdown2 is installed: apt install ifupdown2 |
Reboot Node to Apply
Another way to apply a new network configuration is to reboot the node. In that case the systemd service pvenetcommit will activate the staging interfaces.new file before the networking service will apply that configuration.
Naming Conventions
We currently use the following naming conventions for device names:
-
Ethernet devices: en*, systemd network interface names. This naming scheme is used for new Proxmox VE installations since version 5.0.
-
Ethernet devices: eth[N], where 0 ≤ N (eth0, eth1, …) This naming scheme is used for Proxmox VE hosts which were installed before the 5.0 release. When upgrading to 5.0, the names are kept as-is.
-
Bridge names: Commonly vmbr[N], where 0 ≤ N ≤ 4094 (vmbr0 - vmbr4094), but you can use any alphanumeric string that starts with a character and is at most 10 characters long.
-
Bonds: bond[N], where 0 ≤ N (bond0, bond1, …)
-
VLANs: Simply add the VLAN number to the device name, separated by a period (eno1.50, bond1.30)
This makes it easier to debug networks problems, because the device name implies the device type.
Systemd Network Interface Names
Systemd defines a versioned naming scheme for network device names. The scheme uses the two-character prefix en for Ethernet network devices. The next characters depends on the device driver, device location and other attributes. Some possible patterns are:
-
o<index>[n<phys_port_name>|d<dev_port>] — devices on board
-
s<slot>[f<function>][n<phys_port_name>|d<dev_port>] — devices by hotplug id
-
[P<domain>]p<bus>s<slot>[f<function>][n<phys_port_name>|d<dev_port>] — devices by bus id
-
x<MAC> — devices by MAC address
Some examples for the most common patterns are:
-
eno1 — is the first on-board NIC
-
enp3s0f1 — is function 1 of the NIC on PCI bus 3, slot 0
For a full list of possible device name patterns, see the systemd.net-naming-scheme(7) manpage.
A new version of systemd may define a new version of the network device naming scheme, which it then uses by default. Consequently, updating to a newer systemd version, for example during a major Proxmox VE upgrade, can change the names of network devices and require adjusting the network configuration. To avoid name changes due to a new version of the naming scheme, you can manually pin a particular naming scheme version (see below).
However, even with a pinned naming scheme version, network device names can still change due to kernel or driver updates. In order to avoid name changes for a particular network device altogether, you can manually override its name using a link file (see below).
For more information on network interface names, see Predictable Network Interface Names.
Pinning a specific naming scheme version
You can pin a specific version of the naming scheme for network devices by adding the net.naming-scheme=<version> parameter to the kernel command line. For a list of naming scheme versions, see the systemd.net-naming-scheme(7) manpage.
For example, to pin the version v252, which is the latest naming scheme version for a fresh Proxmox VE 8.0 installation, add the following kernel command-line parameter:
net.naming-scheme=v252
See also this section on editing the kernel command line. You need to reboot for the changes to take effect.
Overriding network device names
You can manually assign a name to a particular network device using a custom systemd.link file. This overrides the name that would be assigned according to the latest network device naming scheme. This way, you can avoid naming changes due to kernel updates, driver updates or newer versions of the naming scheme.
Custom link files should be placed in /etc/systemd/network/ and named <n>-<id>.link, where n is a priority smaller than 99 and id is some identifier. A link file has two sections: [Match] determines which interfaces the file will apply to; [Link] determines how these interfaces should be configured, including their naming.
To assign a name to a particular network device, you need a way to uniquely and permanently identify that device in the [Match] section. One possibility is to match the device’s MAC address using the MACAddress option, as it is unlikely to change.
The [Match] section should also contain a Type option to make sure it only matches the expected physical interface, and not bridge/bond/VLAN interfaces with the same MAC address. In most setups, Type should be set to ether to match only Ethernet devices, but some setups may require other choices. See the systemd.link(5) manpage for more details.
Then, you can assign a name using the Name option in the [Link] section.
Link files are copied to the initramfs, so it is recommended to refresh the initramfs after adding, modifying, or removing a link file:
# update-initramfs -u -k all
For example, to assign the name enwan0 to the Ethernet device with MAC address aa:bb:cc:dd:ee:ff, create a file /etc/systemd/network/10-enwan0.link with the following contents:
[Match] MACAddress=aa:bb:cc:dd:ee:ff Type=ether [Link] Name=enwan0
Do not forget to adjust /etc/network/interfaces to use the new name, and refresh your initramfs as described above. You need to reboot the node for the change to take effect.
It is recommended to assign a name starting with en or eth so that Proxmox VE recognizes the interface as a physical network device which can then be configured via the GUI. Also, you should ensure that the name will not clash with other interface names in the future. One possibility is to assign a name that does not match any name pattern that systemd uses for network interfaces (see above), such as enwan0 in the example above. |
For more information on link files, see the systemd.link(5) manpage.
Choosing a network configuration
Depending on your current network organization and your resources you can choose either a bridged, routed, or masquerading networking setup.
Proxmox VE server in a private LAN, using an external gateway to reach the internet
The Bridged model makes the most sense in this case, and this is also the default mode on new Proxmox VE installations. Each of your Guest system will have a virtual interface attached to the Proxmox VE bridge. This is similar in effect to having the Guest network card directly connected to a new switch on your LAN, the Proxmox VE host playing the role of the switch.
Proxmox VE server at hosting provider, with public IP ranges for Guests
For this setup, you can use either a Bridged or Routed model, depending on what your provider allows.
Proxmox VE server at hosting provider, with a single public IP address
In that case the only way to get outgoing network accesses for your guest systems is to use Masquerading. For incoming network access to your guests, you will need to configure Port Forwarding.
For further flexibility, you can configure VLANs (IEEE 802.1q) and network bonding, also known as "link aggregation". That way it is possible to build complex and flexible virtual networks.
Default Configuration using a Bridge
Bridges are like physical network switches implemented in software. All virtual guests can share a single bridge, or you can create multiple bridges to separate network domains. Each host can have up to 4094 bridges.
The installation program creates a single bridge named vmbr0, which is connected to the first Ethernet card. The corresponding configuration in /etc/network/interfaces might look like this:
auto lo iface lo inet loopback iface eno1 inet manual auto vmbr0 iface vmbr0 inet static address 192.168.10.2/24 gateway 192.168.10.1 bridge-ports eno1 bridge-stp off bridge-fd 0
Virtual machines behave as if they were directly connected to the physical network. The network, in turn, sees each virtual machine as having its own MAC, even though there is only one network cable connecting all of these VMs to the network.
Routed Configuration
Most hosting providers do not support the above setup. For security reasons, they disable networking as soon as they detect multiple MAC addresses on a single interface.
Some providers allow you to register additional MACs through their management interface. This avoids the problem, but can be clumsy to configure because you need to register a MAC for each of your VMs. |
You can avoid the problem by “routing” all traffic via a single interface. This makes sure that all network packets use the same MAC address.
A common scenario is that you have a public IP (assume 198.51.100.5 for this example), and an additional IP block for your VMs (203.0.113.16/28). We recommend the following setup for such situations:
auto lo iface lo inet loopback auto eno0 iface eno0 inet static address 198.51.100.5/29 gateway 198.51.100.1 post-up echo 1 > /proc/sys/net/ipv4/ip_forward post-up echo 1 > /proc/sys/net/ipv4/conf/eno0/proxy_arp auto vmbr0 iface vmbr0 inet static address 203.0.113.17/28 bridge-ports none bridge-stp off bridge-fd 0
Masquerading (NAT) with iptables
Masquerading allows guests having only a private IP address to access the network by using the host IP address for outgoing traffic. Each outgoing packet is rewritten by iptables to appear as originating from the host, and responses are rewritten accordingly to be routed to the original sender.
auto lo iface lo inet loopback auto eno1 #real IP address iface eno1 inet static address 198.51.100.5/24 gateway 198.51.100.1 auto vmbr0 #private sub network iface vmbr0 inet static address 10.10.10.1/24 bridge-ports none bridge-stp off bridge-fd 0 post-up echo 1 > /proc/sys/net/ipv4/ip_forward post-up iptables -t nat -A POSTROUTING -s '10.10.10.0/24' -o eno1 -j MASQUERADE post-down iptables -t nat -D POSTROUTING -s '10.10.10.0/24' -o eno1 -j MASQUERADE
In some masquerade setups with firewall enabled, conntrack zones might be needed for outgoing connections. Otherwise the firewall could block outgoing connections since they will prefer the POSTROUTING of the VM bridge (and not MASQUERADE). |
Adding these lines in the /etc/network/interfaces can fix this problem:
post-up iptables -t raw -I PREROUTING -i fwbr+ -j CT --zone 1 post-down iptables -t raw -D PREROUTING -i fwbr+ -j CT --zone 1
For more information about this, refer to the following links:
Linux Bond
Bonding (also called NIC teaming or Link Aggregation) is a technique for binding multiple NIC’s to a single network device. It is possible to achieve different goals, like make the network fault-tolerant, increase the performance or both together.
High-speed hardware like Fibre Channel and the associated switching hardware can be quite expensive. By doing link aggregation, two NICs can appear as one logical interface, resulting in double speed. This is a native Linux kernel feature that is supported by most switches. If your nodes have multiple Ethernet ports, you can distribute your points of failure by running network cables to different switches and the bonded connection will failover to one cable or the other in case of network trouble.
Aggregated links can improve live-migration delays and improve the speed of replication of data between Proxmox VE Cluster nodes.
There are 7 modes for bonding:
-
Round-robin (balance-rr): Transmit network packets in sequential order from the first available network interface (NIC) slave through the last. This mode provides load balancing and fault tolerance.
-
Active-backup (active-backup): Only one NIC slave in the bond is active. A different slave becomes active if, and only if, the active slave fails. The single logical bonded interface’s MAC address is externally visible on only one NIC (port) to avoid distortion in the network switch. This mode provides fault tolerance.
-
XOR (balance-xor): Transmit network packets based on [(source MAC address XOR’d with destination MAC address) modulo NIC slave count]. This selects the same NIC slave for each destination MAC address. This mode provides load balancing and fault tolerance.
-
Broadcast (broadcast): Transmit network packets on all slave network interfaces. This mode provides fault tolerance.
-
IEEE 802.3ad Dynamic link aggregation (802.3ad)(LACP): Creates aggregation groups that share the same speed and duplex settings. Utilizes all slave network interfaces in the active aggregator group according to the 802.3ad specification.
-
Adaptive transmit load balancing (balance-tlb): Linux bonding driver mode that does not require any special network-switch support. The outgoing network packet traffic is distributed according to the current load (computed relative to the speed) on each network interface slave. Incoming traffic is received by one currently designated slave network interface. If this receiving slave fails, another slave takes over the MAC address of the failed receiving slave.
-
Adaptive load balancing (balance-alb): Includes balance-tlb plus receive load balancing (rlb) for IPV4 traffic, and does not require any special network switch support. The receive load balancing is achieved by ARP negotiation. The bonding driver intercepts the ARP Replies sent by the local system on their way out and overwrites the source hardware address with the unique hardware address of one of the NIC slaves in the single logical bonded interface such that different network-peers use different MAC addresses for their network packet traffic.
If your switch supports the LACP (IEEE 802.3ad) protocol, then we recommend using the corresponding bonding mode (802.3ad). Otherwise you should generally use the active-backup mode.
For the cluster network (Corosync) we recommend configuring it with multiple networks. Corosync does not need a bond for network redundancy as it can switch between networks by itself, if one becomes unusable.
The following bond configuration can be used as distributed/shared storage network. The benefit would be that you get more speed and the network will be fault-tolerant.
auto lo iface lo inet loopback iface eno1 inet manual iface eno2 inet manual iface eno3 inet manual auto bond0 iface bond0 inet static bond-slaves eno1 eno2 address 192.168.1.2/24 bond-miimon 100 bond-mode 802.3ad bond-xmit-hash-policy layer2+3 auto vmbr0 iface vmbr0 inet static address 10.10.10.2/24 gateway 10.10.10.1 bridge-ports eno3 bridge-stp off bridge-fd 0
Another possibility is to use the bond directly as the bridge port. This can be used to make the guest network fault-tolerant.
auto lo iface lo inet loopback iface eno1 inet manual iface eno2 inet manual auto bond0 iface bond0 inet manual bond-slaves eno1 eno2 bond-miimon 100 bond-mode 802.3ad bond-xmit-hash-policy layer2+3 auto vmbr0 iface vmbr0 inet static address 10.10.10.2/24 gateway 10.10.10.1 bridge-ports bond0 bridge-stp off bridge-fd 0
VLAN 802.1Q
A virtual LAN (VLAN) is a broadcast domain that is partitioned and isolated in the network at layer two. So it is possible to have multiple networks (4096) in a physical network, each independent of the other ones.
Each VLAN network is identified by a number often called tag. Network packages are then tagged to identify which virtual network they belong to.
VLAN for Guest Networks
Proxmox VE supports this setup out of the box. You can specify the VLAN tag when you create a VM. The VLAN tag is part of the guest network configuration. The networking layer supports different modes to implement VLANs, depending on the bridge configuration:
-
VLAN awareness on the Linux bridge: In this case, each guest’s virtual network card is assigned to a VLAN tag, which is transparently supported by the Linux bridge. Trunk mode is also possible, but that makes configuration in the guest necessary.
-
"traditional" VLAN on the Linux bridge: In contrast to the VLAN awareness method, this method is not transparent and creates a VLAN device with associated bridge for each VLAN. That is, creating a guest on VLAN 5 for example, would create two interfaces eno1.5 and vmbr0v5, which would remain until a reboot occurs.
-
Open vSwitch VLAN: This mode uses the OVS VLAN feature.
-
Guest configured VLAN: VLANs are assigned inside the guest. In this case, the setup is completely done inside the guest and can not be influenced from the outside. The benefit is that you can use more than one VLAN on a single virtual NIC.
VLAN on the Host
To allow host communication with an isolated network. It is possible to apply VLAN tags to any network device (NIC, Bond, Bridge). In general, you should configure the VLAN on the interface with the least abstraction layers between itself and the physical NIC.
For example, in a default configuration where you want to place the host management address on a separate VLAN.
auto lo iface lo inet loopback iface eno1 inet manual iface eno1.5 inet manual auto vmbr0v5 iface vmbr0v5 inet static address 10.10.10.2/24 gateway 10.10.10.1 bridge-ports eno1.5 bridge-stp off bridge-fd 0 auto vmbr0 iface vmbr0 inet manual bridge-ports eno1 bridge-stp off bridge-fd 0
auto lo iface lo inet loopback iface eno1 inet manual auto vmbr0.5 iface vmbr0.5 inet static address 10.10.10.2/24 gateway 10.10.10.1 auto vmbr0 iface vmbr0 inet manual bridge-ports eno1 bridge-stp off bridge-fd 0 bridge-vlan-aware yes bridge-vids 2-4094
The next example is the same setup but a bond is used to make this network fail-safe.
auto lo iface lo inet loopback iface eno1 inet manual iface eno2 inet manual auto bond0 iface bond0 inet manual bond-slaves eno1 eno2 bond-miimon 100 bond-mode 802.3ad bond-xmit-hash-policy layer2+3 iface bond0.5 inet manual auto vmbr0v5 iface vmbr0v5 inet static address 10.10.10.2/24 gateway 10.10.10.1 bridge-ports bond0.5 bridge-stp off bridge-fd 0 auto vmbr0 iface vmbr0 inet manual bridge-ports bond0 bridge-stp off bridge-fd 0
Disabling IPv6 on the Node
Proxmox VE works correctly in all environments, irrespective of whether IPv6 is deployed or not. We recommend leaving all settings at the provided defaults.
Should you still need to disable support for IPv6 on your node, do so by creating an appropriate sysctl.conf (5) snippet file and setting the proper sysctls, for example adding /etc/sysctl.d/disable-ipv6.conf with content:
net.ipv6.conf.all.disable_ipv6 = 1 net.ipv6.conf.default.disable_ipv6 = 1
This method is preferred to disabling the loading of the IPv6 module on the kernel commandline.
Disabling MAC Learning on a Bridge
By default, MAC learning is enabled on a bridge to ensure a smooth experience with virtual guests and their networks.
But in some environments this can be undesired. Since Proxmox VE 7.3 you can disable MAC learning on the bridge by setting the ‘bridge-disable-mac-learning 1` configuration on a bridge in `/etc/network/interfaces’, for example:
# ... auto vmbr0 iface vmbr0 inet static address 10.10.10.2/24 gateway 10.10.10.1 bridge-ports ens18 bridge-stp off bridge-fd 0 bridge-disable-mac-learning 1
Once enabled, Proxmox VE will manually add the configured MAC address from VMs and Containers to the bridges forwarding database to ensure that guest can still use the network - but only when they are using their actual MAC address.