Installation: Difference between revisions

From Proxmox VE
Jump to navigation Jump to search
No edit summary
No edit summary
 
(10 intermediate revisions by the same user not shown)
Line 4: Line 4:
[[Category:Reference Documentation]]
[[Category:Reference Documentation]]
<pvehide>
<pvehide>
Proxmox VE is based on Debian, therefore the disk image (ISO file) provided
Proxmox VE is based on Debian. This is why the install disk images (ISO files)
by us includes a complete Debian system ("stretch" for version 5.x) as
provided by Proxmox include a complete Debian system as well as all necessary
well as all necessary Proxmox VE packages.
Proxmox VE packages.
Using the installer will guide you through the setup, allowing
See the support table in the FAQ for the
you to partition the local disk(s), apply basic system configurations
relationship between Proxmox VE releases and Debian releases.
(e.g. timezone, language, network) and install all required packages.
The installer will guide you through the setup, allowing you to partition the
Using the provided ISO will get you started in just a few minutes,
local disk(s), apply basic system configurations (for example, timezone,
that&#8217;s why we recommend this method for new and existing users.
language, network) and install all required packages. This process should not
Alternatively, Proxmox VE can be installed on top of an existing Debian
take more than a few minutes. Installing with the provided ISO is the
system. This option is only recommended for advanced users since
recommended method for new and existing users.
detailed knowledge about Proxmox VE is necessary.
Alternatively, Proxmox VE can be installed on top of an existing Debian system. This
option is only recommended for advanced users because detailed knowledge about
Proxmox VE is required.
Using the Proxmox VE Installer
Using the Proxmox VE Installer
You can download the ISO from https://www.proxmox.com/en/downloads.
The installer ISO image includes the following:
It includes the following:
Complete operating system (Debian Linux, 64-bit)
Complete operating system (Debian Linux, 64-bit)
The Proxmox VE installer, which partitions the local disk(s) with ext4,
The Proxmox VE installer, which partitions the local disk(s) with ext4, XFS,
   ext3, xfs or ZFS and installs the operating system.
   BTRFS (technology preview), or ZFS and installs the operating system.
Proxmox VE kernel (Linux) with LXC and KVM support
Proxmox VE Linux kernel with KVM and LXC support
Complete toolset for administering virtual machines, containers and
Complete toolset for administering virtual machines, containers, the host
   all necessary resources
   system, clusters and all necessary resources
Web based management interface for using the toolset
Web-based management interface
During the installation process, the complete server
All existing data on the for installation selected drives will be removed
is used by default and all existing data is removed.
during the installation process. The installer does not add boot menu entries
Please insert the installation media (e.g. USB stick, CD-ROM) and boot
for other operating systems.
from it.
Please insert the prepared installation media
After choosing the correct entry (e.g. Boot from USB) the Proxmox VE menu
(for example, USB flash drive or CD-ROM) and boot from it.
will be displayed, you can now select one of the following options:
Make sure that booting from the installation medium (for example, USB) is
Install Proxmox VE
enabled in your server&#8217;s firmware settings. Secure boot needs to be disabled
Start normal installation.
when booting an installer prior to Proxmox VE version 8.1.
It is possible to only use the keyboard to progress through the
After choosing the correct entry (e.g. Boot from USB) the Proxmox VE menu will be
installation wizard. Buttons can be pressed by pressing down the ALT
displayed and one of the following options can be selected:
key, combined with the underlined character from the respective Button.
Install Proxmox VE (Graphical)
For example, ALT + N to press a Next button.
Starts the normal installation.
Install Proxmox VE (Debug mode)
It&#8217;s possible to use the installation wizard with a keyboard only. Buttons
Start installation in debug mode. It opens a shell console at several
can be clicked by pressing the ALT key combined with the underlined character
installation steps, so that you can debug things if something goes
from the respective button. For example, ALT + N to press a Next button.
wrong. Please press CTRL-D to exit those debug consoles and continue
Install Proxmox VE (Terminal UI)
installation. This option is mostly for developers and not meant for
Starts the console-mode installation wizard. It provides the same overall
general use.
installation experience as the graphical installer, but has generally better
Rescue Boot
compatibility with very old and very new hardware.
This option allows you to boot an existing installation. It searches
Both modes use the same code base for the actual installation process to
all attached hard disks and, if it finds an existing installation,
benefit from more than a decade of bug fixes and ensure feature parity.
boots directly into that disk using the existing Linux kernel. This
The Terminal UI option can be used in case the graphical installer does
can be useful if there are problems with the boot block (grub), or the
not work correctly, due to e.g. driver issues.
BIOS is unable to read the boot block from the disk.
Advanced Options: Install Proxmox VE (Graphical, Debug Mode)
Test Memory
Starts the installation in debug mode. A console will be opened at several
Runs memtest86+. This is useful to check if your memory is
installation steps. This helps to debug the situation if something goes wrong.
functional and error free.
To exit a debug console, press CTRL-D. This option can be used to boot a live
You normally select Install Proxmox VE to start the installation.
system with all basic tools available. You can use it, for example, to
After that you get prompted to select the target hard disk(s). The
repair a degraded ZFS rpool or fix the
Options button lets you select the target file system, which
bootloader for an existing Proxmox VE setup.
defaults to ext4. The installer uses LVM if you select ext3,
Advanced Options: Install Proxmox VE (Terminal UI, Debug Mode)
ext4 or xfs as file system, and offers additional option to
Same as the graphical debug mode, but preparing the system to run the
restrict LVM space (see below)
terminal-based installer instead.
You can also use ZFS as file system. ZFS supports several software RAID
Advanced Options: Install Proxmox VE (Serial Console Debug Mode)
levels, so this is specially useful if you do not have a hardware RAID
Same the terminal-based debug mode, but additionally sets up the Linux kernel to
controller. The Options button lets you select the ZFS RAID level, and
use the (first) serial port of the machine for in- and output.
you can choose disks there. Additionally you can set additional options (see
Advanced Options: Rescue Boot
below).
With this option you can boot an existing installation. It searches all attached
The next page just asks for basic configuration options like your
hard disks. If it finds an existing installation, it boots directly into that
location, the time zone and keyboard layout. The location is used to
disk using the Linux kernel from the ISO. This can be useful if there are
select a download server near you to speed up updates. The installer is
problems with the bootloader (GRUB/systemd-boot) or the BIOS/UEFI is unable to
usually able to auto detect those settings, so you only need to change
read the boot block from the disk.
them in rare situations when auto detection fails, or when you want to
Advanced Options: Test Memory (memtest86+)
use some special keyboard layout not commonly used in your country.
Runs memtest86+. This is useful to check if the memory is functional and free
You then need to specify an email address and the superuser (root)
of errors. Secure Boot must be turned off in the UEFI firmware setup utility to
password. The password must have at least 5 characters, but we highly
run this option.
recommend to use stronger passwords - here are some guidelines:
After selecting Install Proxmox VE and accepting the EULA, the prompt to select the
target hard disk(s) will appear. The Options button opens the dialog to select
the target file system.
The default file system is ext4. The Logical Volume Manager (LVM) is used when
ext4 or xfs is selected. Additional options to restrict LVM space
can also be set (see below).
Proxmox VE can be installed on ZFS. As ZFS offers several software RAID levels, this
is an option for systems that don&#8217;t have a hardware RAID controller. The target
disks must be selected in the Options dialog. More ZFS specific settings can
be changed under Advanced Options (see below).
ZFS on top of any hardware RAID is not supported and can result in data
loss.
The next page asks for basic configuration options like the location, the time
zone, and keyboard layout. The location is used to select a download server
close by to speed up updates. The installer usually auto-detects these settings.
They only need to be changed in the rare case that auto detection fails or a
different keyboard layout should be used.
Next the password of the superuser (root) and an email address needs to be
specified. The password must consist of at least 5 characters. It&#8217;s highly
recommended to use a stronger password. Some guidelines are:
Use a minimum password length of 12 to 14 characters.
Use a minimum password length of 12 to 14 characters.
Include lowercase and uppercase alphabetic characters, numbers and symbols.
Include lowercase and uppercase alphabetic characters, numbers, and symbols.
Avoid character repetition, keyboard patterns, dictionary words,
Avoid character repetition, keyboard patterns, common dictionary words,
   letter or number sequences, usernames, relative or pet names,
   letter or number sequences, usernames, relative or pet names, romantic links
   romantic links (current or past) and biographical information (e.g.,
   (current or past), and biographical information (for example ID numbers,
   ID numbers, ancestors' names or dates).
   ancestors' names or dates).
It is sometimes necessary to send notifications to the system
The email address is used to send notifications to the system administrator.
administrator, for example:
For example:
Information about available package updates.
Information about available package updates.
Error messages from periodic CRON jobs.
Error messages from periodic CRON jobs.
All those notification mails will be sent to the specified email
The last step is the network configuration. Network interfaces that are UP show
address.
a filled circle in front of their name in the drop down menu. Please note that
The last step is the network configuration. Please note that you can
during installation you can either use an IPv4 or IPv6 address, but not both. To
use either IPv4 or IPv6 here, but not both. If you want to configure a
configure a dual stack node, add additional IP addresses after the installation.
dual stack node, you can easily do that after installation.
The next step shows a summary of the previously selected options. Re-check every
If you press Next now, installation starts to format disks, and
setting and use the Previous button if a setting needs to be changed. To
copies packages to the target. Please wait until that is finished,
accept, press Install. The installation starts to format disks and copies
then remove the installation media and restart your system.
packages to the target. Please wait until this step has finished; then remove
Further configuration is done via the Proxmox web interface. Just
the installation medium and restart your system.
point your browser to the IP address given during installation
If the installation failed, check out specific errors on the second TTY
(https://youripaddress:8006).
(&#8216;CTRL + ALT + F2&#8217;) and ensure that the systems meets the
Default login is "root" (realm PAM) and the root password is
minimum requirements. If the installation
defined during the installation process.
is still not working, look at the how to get help chapter.
Further configuration is done via the Proxmox web interface. Point your browser
to the IP address given during installation (https://youripaddress:8006).
Default login is "root" (realm PAM) and the root password was defined
during the installation process.
Advanced LVM Configuration Options
Advanced LVM Configuration Options
The installer creates a Volume Group (VG) called pve, and additional
The installer creates a Volume Group (VG) called pve, and additional Logical
Logical Volumes (LVs) called root, data and swap. The size of
Volumes (LVs) called root, data, and swap. To control the size of these
those volumes can be controlled with:
volumes use:
hdsize
hdsize
Defines the total HD size to be used. This way you can save free
Defines the total hard disk size to be used. This way you can reserve free space
space on the HD for further partitioning (i.e. for an additional PV
on the hard disk for further partitioning (for example for an additional PV and
and VG on the same hard disk that can be used for LVM storage).
VG on the same hard disk that can be used for LVM storage).
swapsize
swapsize
Defines the size of the swap volume. The default is the size of the
Defines the size of the swap volume. The default is the size of the installed
installed memory, minimum 4 GB and maximum 8 GB. The resulting value cannot
memory, minimum 4 GB and maximum 8 GB. The resulting value cannot be greater
be greater than hdsize/8.
than hdsize/8.
If set to 0, no swap volume will be created.
If set to 0, no swap volume will be created.
maxroot
maxroot
Line 116: Line 140:
datasize = hdsize - rootsize - swapsize - minfree
datasize = hdsize - rootsize - swapsize - minfree
Where datasize cannot be bigger than maxvz.
Where datasize cannot be bigger than maxvz.
In case of LVM thin, the data pool will only be created if datasize
In case of LVM thin, the data pool will only be created if datasize is
is bigger than 4GB.
bigger than 4GB.
If set to 0, no data volume will be created and the storage
If set to 0, no data volume will be created and the storage
configuration will be adapted accordingly.
configuration will be adapted accordingly.
minfree
minfree
Defines the amount of free space left in LVM volume group pve.
Defines the amount of free space left in the LVM volume group pve. With more
With more than 128GB storage available the default is 16GB, else hdsize/8
than 128GB storage available the default is 16GB, else hdsize/8 will be used.
will be used.
LVM requires free space in the VG for snapshot creation (not required for
LVM requires free space in the VG for snapshot creation (not
lvmthin snapshots).
required for lvmthin snapshots).
Advanced ZFS Configuration Options
Advanced ZFS Configuration Options
The installer creates a ZFS pool rpool. When selecting ZFS, no swap space is
The installer creates the ZFS pool rpool. No swap space is created but you can
created by default. You can leave some unpartitioned space for swap or create
reserve some unpartitioned space on the install disks for swap. You can also
a swap zvol after installation, though the latter can lead to problems
create a swap zvol after the installation, although this can lead to problems.
(see ZFS swap notes).
(see ZFS swap notes).
ashift
ashift
Defines the ashift value for the created pool. The ashift needs
Defines the ashift value for the created pool. The ashift needs to be set at
to be set at least to the sector-size of the underlying disks (2 to
least to the sector-size of the underlying disks (2 to the power of ashift is
the power of ashift is the sector-size), or any disk,
the sector-size), or any disk which might be put in the pool (for example the
which might be put in the pool (e.g. during replacing a defective disk).
replacement of a defective disk).
compress
compress
Defines whether compression is enabled for rpool.
Defines whether compression is enabled for rpool.
Line 144: Line 167:
semantics, and why this does not replace redundancy on disk-level.
semantics, and why this does not replace redundancy on disk-level.
hdsize
hdsize
Defines the total HD size to be used. This way you can save free
Defines the total hard disk size to be used. This is useful to save free space
space on the HD(s) for further partitioning (e.g. for creating a swap-partition).
on the hard disk(s) for further partitioning (for example to create a
hdsize is only honored for bootable disks, i.e., only the first disk or
swap-partition). hdsize is only honored for bootable disks, that is only the
mirror for RAID0, RAID1 or RAID10, and all disks in RAID-Z[123].
first disk or mirror for RAID0, RAID1 or RAID10, and all disks in RAID-Z[123].
ZFS Performance Tips
ZFS Performance Tips
ZFS uses a lot of memory, so it is best to add additional RAM if you
ZFS works best with a lot of memory. If you intend to use ZFS make sure to have
want to use ZFS. A good calculation is 4GB plus 1GB RAM for each TB
enough RAM available for it. A good calculation is 4GB plus 1GB RAM for each TB
RAW disk space.
RAW disk space.
ZFS also provides the feature to use a fast SSD drive as write cache. The
ZFS can use a dedicated drive as write cache, called the ZFS Intent Log (ZIL).
write cache is called the ZFS Intent Log (ZIL). You can add that after
Use a fast drive (SSD) for it. It can be added after installation with the
installation using the following command:
following command:
zpool add &lt;pool-name&gt; log &lt;/dev/path_to_fast_ssd&gt;
# zpool add &lt;pool-name&gt; log &lt;/dev/path_to_fast_ssd&gt;
Install from USB Stick
Adding the nomodeset Kernel Parameter
Install Proxmox VE on Debian Stretch
Problems may arise on very old or very new hardware due to graphics drivers. If
the installation hangs during the boot. In that case, you can try adding the
nomodeset parameter. This prevents the Linux kernel from loading any
graphics drivers and forces it to continue using the BIOS/UEFI-provided
framebuffer.
On the Proxmox VE bootloader menu, navigate to Install Proxmox VE (Terminal UI) and
press e to edit the entry. Using the arrow keys, navigate to the line starting
with linux, move the cursor to the end of that line and add the
parameter nomodeset, separated by a space from the pre-existing last
parameter.
Then press Ctrl-X or F10 to boot the configuration.
Video Tutorials
Video Tutorials
List of all official tutorials on our
See the list of all official tutorials on our
  Proxmox VE YouTube Channel
Proxmox VE YouTube Channel
Tutorials in Spanish language on
  ITexperts.es
  YouTube Play List
See Also
See Also
Prepare Installation Media
Install Proxmox VE on Debian Buster
System Requirements
System Requirements
Package Repositories
Package Repositories

Latest revision as of 17:30, 6 March 2024

Proxmox VE is based on Debian. This is why the install disk images (ISO files) provided by Proxmox include a complete Debian system as well as all necessary Proxmox VE packages.

Tip See the support table in the FAQ for the relationship between Proxmox VE releases and Debian releases.

The installer will guide you through the setup, allowing you to partition the local disk(s), apply basic system configurations (for example, timezone, language, network) and install all required packages. This process should not take more than a few minutes. Installing with the provided ISO is the recommended method for new and existing users.

Alternatively, Proxmox VE can be installed on top of an existing Debian system. This option is only recommended for advanced users because detailed knowledge about Proxmox VE is required.

Using the Proxmox VE Installer

The installer ISO image includes the following:

  • Complete operating system (Debian Linux, 64-bit)

  • The Proxmox VE installer, which partitions the local disk(s) with ext4, XFS, BTRFS (technology preview), or ZFS and installs the operating system

  • Proxmox VE Linux kernel with KVM and LXC support

  • Complete toolset for administering virtual machines, containers, the host system, clusters and all necessary resources

  • Web-based management interface

Note All existing data on the selected drives will be removed during the installation process. The installer does not add boot menu entries for other operating systems.

Please insert the prepared installation media (for example, USB flash drive or CD-ROM) and boot from it.

Tip Make sure that booting from the installation medium (for example, USB) is enabled in your server’s firmware settings. Secure boot needs to be disabled when booting an installer prior to Proxmox VE version 8.1.
screenshot/pve-grub-menu.png

After choosing the correct entry (for example, Boot from USB) the Proxmox VE menu will be displayed, and one of the following options can be selected:

Install Proxmox VE (Graphical)

Starts the normal installation.

Tip It’s possible to use the installation wizard with a keyboard only. Buttons can be clicked by pressing the ALT key combined with the underlined character from the respective button. For example, ALT + N to press a Next button.
Install Proxmox VE (Terminal UI)

Starts the terminal-mode installation wizard. It provides the same overall installation experience as the graphical installer, but has generally better compatibility with very old and very new hardware.

Install Proxmox VE (Terminal UI, Serial Console)

Starts the terminal-mode installation wizard, additionally setting up the Linux kernel to use the (first) serial port of the machine for in- and output. This can be used if the machine is completely headless and only has a serial console available.

screenshot/pve-tui-installer.png

Both modes use the same code base for the actual installation process to benefit from more than a decade of bug fixes and ensure feature parity.

Tip The Terminal UI option can be used in case the graphical installer does not work correctly, due to e.g. driver issues. See also adding the nomodeset kernel parameter.
Advanced Options: Install Proxmox VE (Graphical, Debug Mode)

Starts the installation in debug mode. A console will be opened at several installation steps. This helps to debug the situation if something goes wrong. To exit a debug console, press CTRL-D. This option can be used to boot a live system with all basic tools available. You can use it, for example, to repair a degraded ZFS rpool or fix the bootloader for an existing Proxmox VE setup.

Advanced Options: Install Proxmox VE (Terminal UI, Debug Mode)

Same as the graphical debug mode, but preparing the system to run the terminal-based installer instead.

Advanced Options: Install Proxmox VE (Serial Console Debug Mode)

Same the terminal-based debug mode, but additionally sets up the Linux kernel to use the (first) serial port of the machine for in- and output.

Advanced Options: Install Proxmox VE (Automated)

Starts the installer in unattended mode, even if the ISO has not been appropriately prepared for an automated installation. This option can be used to gather hardware details or might be useful to debug an automated installation setup. See Unattended Installation for more information.

Advanced Options: Rescue Boot

With this option you can boot an existing installation. It searches all attached hard disks. If it finds an existing installation, it boots directly into that disk using the Linux kernel from the ISO. This can be useful if there are problems with the bootloader (GRUB/systemd-boot) or the BIOS/UEFI is unable to read the boot block from the disk.

Advanced Options: Test Memory (memtest86+)

Runs memtest86+. This is useful to check if the memory is functional and free of errors. Secure Boot must be turned off in the UEFI firmware setup utility to run this option.

You normally select Install Proxmox VE (Graphical) to start the installation.

screenshot/pve-select-target-disk.png

The first step is to read our EULA (End User License Agreement). Following this, you can select the target hard disk(s) for the installation.

Caution By default, the whole server is used and all existing data is removed. Make sure there is no important data on the server before proceeding with the installation.

The Options button lets you select the target file system, which defaults to ext4. The installer uses LVM if you select ext4 or xfs as a file system, and offers additional options to restrict LVM space (see below).

Proxmox VE can also be installed on ZFS. As ZFS offers several software RAID levels, this is an option for systems that don’t have a hardware RAID controller. The target disks must be selected in the Options dialog. More ZFS specific settings can be changed under Advanced Options.

Warning ZFS on top of any hardware RAID is not supported and can result in data loss.
screenshot/pve-select-location.png

The next page asks for basic configuration options like your location, time zone, and keyboard layout. The location is used to select a nearby download server, in order to increase the speed of updates. The installer is usually able to auto-detect these settings, so you only need to change them in rare situations when auto-detection fails, or when you want to use a keyboard layout not commonly used in your country.

screenshot/pve-set-password.png

Next the password of the superuser (root) and an email address needs to be specified. The password must consist of at least 5 characters. It’s highly recommended to use a stronger password. Some guidelines are:

  • Use a minimum password length of at least 12 characters.

  • Include lowercase and uppercase alphabetic characters, numbers, and symbols.

  • Avoid character repetition, keyboard patterns, common dictionary words, letter or number sequences, usernames, relative or pet names, romantic links (current or past), and biographical information (for example ID numbers, ancestors' names or dates).

The email address is used to send notifications to the system administrator. For example:

  • Information about available package updates.

  • Error messages from periodic cron jobs.

screenshot/pve-setup-network.png

All those notification mails will be sent to the specified email address.

The last step is the network configuration. Network interfaces that are UP show a filled circle in front of their name in the drop down menu. Please note that during installation you can either specify an IPv4 or IPv6 address, but not both. To configure a dual stack node, add additional IP addresses after the installation.

screenshot/pve-installation.png

The next step shows a summary of the previously selected options. Please re-check every setting and use the Previous button if a setting needs to be changed.

After clicking Install, the installer will begin to format the disks and copy packages to the target disk(s). Please wait until this step has finished; then remove the installation medium and restart your system.

screenshot/pve-install-summary.png

Copying the packages usually takes several minutes, mostly depending on the speed of the installation medium and the target disk performance.

When copying and setting up the packages has finished, you can reboot the server. This will be done automatically after a few seconds by default.

Installation Failure

If the installation failed, check out specific errors on the second TTY (CTRL + ALT + F2) and ensure that the systems meets the minimum requirements.

If the installation is still not working, look at the how to get help chapter.

Accessing the Management Interface Post-Installation

screenshot/gui-login-window.png

After a successful installation and reboot of the system you can use the Proxmox VE web interface for further configuration.

  1. Point your browser to the IP address given during the installation and port 8006, for example: https://youripaddress:8006

  2. Log in using the root (realm PAM) username and the password chosen during installation.

  3. Upload your subscription key to gain access to the Enterprise repository. Otherwise, you will need to set up one of the public, less tested package repositories to get updates for security fixes, bug fixes, and new features.

  4. Check the IP configuration and hostname.

  5. Check the timezone.

  6. Check your Firewall settings.

Advanced LVM Configuration Options

The installer creates a Volume Group (VG) called pve, and additional Logical Volumes (LVs) called root, data, and swap, if ext4 or xfs is used. To control the size of these volumes use:

hdsize

Defines the total hard disk size to be used. This way you can reserve free space on the hard disk for further partitioning (for example for an additional PV and VG on the same hard disk that can be used for LVM storage).

swapsize

Defines the size of the swap volume. The default is the size of the installed memory, minimum 4 GB and maximum 8 GB. The resulting value cannot be greater than hdsize/8.

Note If set to 0, no swap volume will be created.
maxroot

Defines the maximum size of the root volume, which stores the operation system. The maximum limit of the root volume size is hdsize/4.

maxvz

Defines the maximum size of the data volume. The actual size of the data volume is:

datasize = hdsize - rootsize - swapsize - minfree

Where datasize cannot be bigger than maxvz.

Note In case of LVM thin, the data pool will only be created if datasize is bigger than 4GB.
Note If set to 0, no data volume will be created and the storage configuration will be adapted accordingly.
minfree

Defines the amount of free space that should be left in the LVM volume group pve. With more than 128GB storage available, the default is 16GB, otherwise hdsize/8 will be used.

Note LVM requires free space in the VG for snapshot creation (not required for lvmthin snapshots).

Advanced ZFS Configuration Options

The installer creates the ZFS pool rpool, if ZFS is used. No swap space is created but you can reserve some unpartitioned space on the install disks for swap. You can also create a swap zvol after the installation, although this can lead to problems (see ZFS swap notes).

ashift

Defines the ashift value for the created pool. The ashift needs to be set at least to the sector-size of the underlying disks (2 to the power of ashift is the sector-size), or any disk which might be put in the pool (for example the replacement of a defective disk).

compress

Defines whether compression is enabled for rpool.

checksum

Defines which checksumming algorithm should be used for rpool.

copies

Defines the copies parameter for rpool. Check the zfs(8) manpage for the semantics, and why this does not replace redundancy on disk-level.

ARC max size

Defines the maximum size the ARC can grow to and thus limits the amount of memory ZFS will use. See also the section on how to limit ZFS memory usage for more details.

hdsize

Defines the total hard disk size to be used. This is useful to save free space on the hard disk(s) for further partitioning (for example to create a swap-partition). hdsize is only honored for bootable disks, that is only the first disk or mirror for RAID0, RAID1 or RAID10, and all disks in RAID-Z[123].

Advanced BTRFS Configuration Options

No swap space is created when BTRFS is used but you can reserve some unpartitioned space on the install disks for swap. You can either create a separate partition, BTRFS subvolume or a swapfile using the btrfs filesystem mkswapfile command.

compress

Defines whether compression is enabled for the BTRFS subvolume. Different compression algorithms are supported: on (equivalent to zlib), zlib, lzo and zstd. Defaults to off.

hdsize

Defines the total hard disk size to be used. This is useful to save free space on the hard disk(s) for further partitioning (for example, to create a swap partition).

ZFS Performance Tips

ZFS works best with a lot of memory. If you intend to use ZFS make sure to have enough RAM available for it. A good calculation is 4GB plus 1GB RAM for each TB RAW disk space.

ZFS can use a dedicated drive as write cache, called the ZFS Intent Log (ZIL). Use a fast drive (SSD) for it. It can be added after installation with the following command:

# zpool add <pool-name> log </dev/path_to_fast_ssd>

Adding the nomodeset Kernel Parameter

Problems may arise on very old or very new hardware due to graphics drivers. If the installation hangs during boot, you can try adding the nomodeset parameter. This prevents the Linux kernel from loading any graphics drivers and forces it to continue using the BIOS/UEFI-provided framebuffer.

On the Proxmox VE bootloader menu, navigate to Install Proxmox VE (Terminal UI) and press e to edit the entry. Using the arrow keys, navigate to the line starting with linux, move the cursor to the end of that line and add the parameter nomodeset, separated by a space from the pre-existing last parameter.

Then press Ctrl-X or F10 to boot the configuration.

Unattended Installation

It is possible to install Proxmox VE automatically in an unattended manner. This enables you to fully automate the setup process on bare-metal. Once the installation is complete and the host has booted up, automation tools like Ansible can be used to further configure the installation.

The necessary options for the installer must be provided in an answer file. This file allows the use of filter rules to determine which disks and network cards should be used.

To use the automated installation, it is first necessary to prepare an installation ISO. Visit our wiki for more details and information on the unattended installation.

Video Tutorials

See the list of all official tutorials on our Proxmox VE YouTube Channel