Windows 2003 guest best practices: Difference between revisions
(Add in Category: Qemu/KVM) |
|||
(7 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
==Introduction== | ==Introduction== | ||
This is a set of best practices to follow when installing a Windows 2003 guest on a Proxmox VE server. Right now it's a work in progress | This is a set of best practices to follow when installing a Windows 2003 guest on a Proxmox VE server. Right now it's a work in progress. Please feel free to add to it, even if just to pose a potential best practice. | ||
== | ==Disk== | ||
===raw vs qcow2=== | |||
Raw file format provides better performance while qcow2 offers advanced features such as copy on write and snapshots. | |||
===virtio storage drivers=== | |||
Use virtio dirvers for best performance. See http://pve.proxmox.com/wiki/Paravirtualized_Block_Drivers_for_Windows | |||
Note: the latest VirtIO iso do not include drivers for Windows 2003. You need to download an older version. | |||
== Network == | |||
=== E1000 NIC === | |||
Use e1000 NIC. It's stable and performs well. BUT only with the latest drivers from Intel, [http://downloadcenter.intel.com/Detail_Desc.aspx?agr=Y&DwnldID=18719 download from intel.com]! (If you use the integrated drivers, the device manager shows a working NIC, but it does not.) | |||
'''Windows Server 2003 R2 SP2''' ships with drivers that do work, but the ones from intel are newer. | |||
=== Virtio === | |||
Use virtio driver as these are kept updated by Fedora virtio NIC drivers need to be loaded post install & can be found here : https://fedorapeople.org/groups/virt/virtio-win/direct-downloads/latest-virtio/ Information on install can be found here : http://pve.proxmox.com/wiki/Paravirtualized_Network_Drivers_for_Windows | |||
Note: the latest VirtIO iso do not include drivers for Windows 2003. You need to download an older version. | |||
=== Packet Capture Fix === | |||
I highly recommend to add this regfix http://www.intel.com/support/de/network/sb/cs-005897.htm (http://www.intel.com/support/network/sb/CS-005897.htm?wapkw=%284D36E972%29 in english). HKEY_LOCAL_MACHINE\SYSTEM\ControlSet001\Control\Class\{4D36E972-E325-11CE-BFC1-08002BE10318}\00xx where you need to search for your network card an add a DWORD "MonitorModeEnabled"="1". ControlSet001 can be CurrentControlSet. | |||
=== KVM Network Performance === | |||
Apply the changes mentioned on the [http://www.linux-kvm.org/page/WindowsGuestDrivers/kvmnet/registry KVM Windows TCP/IP Performance] page. | |||
== Miscellaneous hints == | |||
=== Power management === | |||
* In order for the Windows 2003 guest to shutdown cleanly in the event of a shutdown on the Proxmox VE host you need to: | * In order for the Windows 2003 guest to shutdown cleanly in the event of a shutdown on the Proxmox VE host you need to: | ||
# enable (Start -> Run -> secpol.msc -> "Security Settings\Local Policies\Security Options") | # enable (Start -> Run -> secpol.msc -> "Security Settings\Local Policies\Security Options") | ||
Line 56: | Line 85: | ||
NOTE: For this policy to be visible in the ''Group Policy Object Editor'' the ''Only show policy settings that can be fully managed'' filter must be unchecked. | NOTE: For this policy to be visible in the ''Group Policy Object Editor'' the ''Only show policy settings that can be fully managed'' filter must be unchecked. | ||
== | === Clock Drift === | ||
If you have any problems with the time on your VM drifting, please see the [[Guest Time drift|Guest Time Drift]] document. | |||
== | ==Sources and further reading== | ||
[[Windows 2012 guest best practices]] | |||
[[Windows 2008 guest best practices]] | |||
[http://www.linux-kvm.org/page/Tuning_KVM www.linux-kvm.org/page/Tuning_KVM] | [http://www.linux-kvm.org/page/Tuning_KVM www.linux-kvm.org/page/Tuning_KVM] | ||
[[Category: HOWTO]] | [[Category: HOWTO]] | ||
[[Category: Qemu/KVM]] | |||
[[ |
Latest revision as of 14:14, 6 October 2016
Introduction
This is a set of best practices to follow when installing a Windows 2003 guest on a Proxmox VE server. Right now it's a work in progress. Please feel free to add to it, even if just to pose a potential best practice.
Disk
raw vs qcow2
Raw file format provides better performance while qcow2 offers advanced features such as copy on write and snapshots.
virtio storage drivers
Use virtio dirvers for best performance. See http://pve.proxmox.com/wiki/Paravirtualized_Block_Drivers_for_Windows
Note: the latest VirtIO iso do not include drivers for Windows 2003. You need to download an older version.
Network
E1000 NIC
Use e1000 NIC. It's stable and performs well. BUT only with the latest drivers from Intel, download from intel.com! (If you use the integrated drivers, the device manager shows a working NIC, but it does not.)
Windows Server 2003 R2 SP2 ships with drivers that do work, but the ones from intel are newer.
Virtio
Use virtio driver as these are kept updated by Fedora virtio NIC drivers need to be loaded post install & can be found here : https://fedorapeople.org/groups/virt/virtio-win/direct-downloads/latest-virtio/ Information on install can be found here : http://pve.proxmox.com/wiki/Paravirtualized_Network_Drivers_for_Windows
Note: the latest VirtIO iso do not include drivers for Windows 2003. You need to download an older version.
Packet Capture Fix
I highly recommend to add this regfix http://www.intel.com/support/de/network/sb/cs-005897.htm (http://www.intel.com/support/network/sb/CS-005897.htm?wapkw=%284D36E972%29 in english). HKEY_LOCAL_MACHINE\SYSTEM\ControlSet001\Control\Class\{4D36E972-E325-11CE-BFC1-08002BE10318}\00xx where you need to search for your network card an add a DWORD "MonitorModeEnabled"="1". ControlSet001 can be CurrentControlSet.
KVM Network Performance
Apply the changes mentioned on the KVM Windows TCP/IP Performance page.
Miscellaneous hints
Power management
- In order for the Windows 2003 guest to shutdown cleanly in the event of a shutdown on the Proxmox VE host you need to:
- enable (Start -> Run -> secpol.msc -> "Security Settings\Local Policies\Security Options")
- "Shutdown: Allow system to be shut down without having to log on".
- "Interactive logon: Do not require CTRL+ALT+DEL"
- disable logon screen screensaver using regedit
REGEDIT4
[HKEY_USERS\.DEFAULT\Control Panel\Desktop]
"ScreenSaveActive"="0"
- Optional: It may also be useful to set Shutdown Warning Dialog Timeout. This can be done with the following .reg file
Windows Registry Editor Version 5.00
[HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Windows]
"ShutdownWarningDialogTimeout"=dword:00000001
Alternatively you can you can use the following adm template to apply it via GPO
CLASS MACHINE
CATEGORY "otherSystem"
KEYNAME "SOFTWARE\Microsoft\Windows NT\CurrentVersion\Windows"
POLICY "Shutdown Warning Dialog Timeout"
KEYNAME "SOFTWARE\Microsoft\Windows NT\CurrentVersion\Windows"
VALUENAME "ShutdownWarningDialogTimeout"
VALUEON NUMERIC 1
VALUEOFF DELETE
PART "Shutdown Warning Dialog Timeout" NUMERIC
KEYNAME "SOFTWARE\Microsoft\Windows NT\CurrentVersion\Windows"
VALUENAME "ShutdownWarningDialogTimeout"
REQUIRED
MIN 0
MAX 9999
DEFAULT 1
END PART
END POLICY
END CATEGORY
CLASS USER
NOTE: For this policy to be visible in the Group Policy Object Editor the Only show policy settings that can be fully managed filter must be unchecked.
Clock Drift
If you have any problems with the time on your VM drifting, please see the Guest Time Drift document.
Sources and further reading
Windows 2012 guest best practices