System Requirements: Difference between revisions

From Proxmox VE
Jump to navigation Jump to search
m (Protected "System Requirements" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
No edit summary
 
(4 intermediate revisions by the same user not shown)
Line 4: Line 4:
[[Category:Reference Documentation]]
[[Category:Reference Documentation]]
<pvehide>
<pvehide>
For production servers, high quality server equipment is needed. Keep
We recommend using high quality server hardware, when running Proxmox VE in
in mind, if you run 10 Virtual Servers on one machine and you then
production. To further decrease the impact of a failed host, you can run Proxmox VE in
experience a hardware failure, 10 services are lost. Proxmox VE
a cluster with highly available (HA) virtual machines and containers.
supports clustering, this means that multiple Proxmox VE installations
Proxmox VE can use local storage (DAS), SAN, NAS, and distributed storage like Ceph
can be centrally managed thanks to the included cluster functionality.
RBD. For details see chapter storage.
Proxmox VE can use local storage (DAS), SAN, NAS and also distributed
storage (Ceph RBD). For details see chapter storage.
Minimum Requirements, for Evaluation
Minimum Requirements, for Evaluation
These minimum requirements are for evaluation purposes only and should not be
used in production.
CPU: 64bit (Intel EMT64 or AMD64)
CPU: 64bit (Intel EMT64 or AMD64)
Intel VT/AMD-V capable CPU/Mainboard for KVM Full Virtualization support
Intel VT/AMD-V capable CPU/motherboard for KVM full virtualization support
RAM: 1 GB RAM, plus additional RAM used for guests
RAM: 1 GB RAM, plus additional RAM needed for guests
Hard drive
Hard drive
One NIC
One network card (NIC)
Recommended System Requirements
Recommended System Requirements
CPU: 64bit (Intel EMT64 or AMD64), Multi core CPU recommended
Intel EMT64 or AMD64 with Intel VT/AMD-V CPU flag.
Intel VT/AMD-V capable CPU/Mainboard for KVM Full Virtualization support
Memory: Minimum 2 GB for the OS and Proxmox VE services, plus designated memory for
RAM: 8 GB RAM, plus additional RAM used for guests
  guests. For Ceph and ZFS, additional memory is required; approximately 1GB of
Hardware RAID with batteries protected write cache (&#8220;BBU&#8221;) or flash
  memory for every TB of used storage.
based protection
Fast and redundant storage, best results are achieved with SSDs.
Fast hard drives, best results with 15k rpm SAS, Raid10
OS storage: Use a hardware RAID with battery protected write cache (&#8220;BBU&#8221;)
At least two NICs, depending on the used storage technology you need more
  or non-RAID with ZFS (optional SSD for ZIL).
VM storage:
For local storage, use either a hardware RAID with battery backed write cache
  (BBU) or non-RAID for ZFS and Ceph. Neither ZFS nor Ceph are compatible with a
  hardware RAID controller.
Shared and distributed storage is possible.
Redundant (Multi-)Gbit NICs, with additional NICs depending on the preferred
  storage technology and cluster setup.
For PCI(e) passthrough the CPU needs to support the VT-d/AMD-d flag.
Simple Performance Overview
Simple Performance Overview
On an installed Proxmox VE system, you can run the included pveperf script
To get an overview of the CPU and hard disk performance on an installed Proxmox VE
to obtain an overview of the CPU and hard disk performance.
system, run the included pveperf tool.
this is just a very quick and general benchmark. More detailed tests
This is just a very quick and general benchmark. More detailed tests are
are recommended, especially regarding the I/O performance of your system.
recommended, especially regarding the I/O performance of your system.
Supported web browsers for accessing the web interface
Supported Web Browsers for Accessing the Web Interface
To use the web interface you need a modern browser, this includes:
To access the web-based user interface, we recommend using one of the following
Firefox, a release from the current year, or the latest Extended
browsers:
Support Release
Firefox, a release from the current year, or the latest Extended Support Release
Chrome, a release from the current year
Chrome, a release from the current year
the Microsoft currently supported versions of Internet Explorer (as
Microsoft&#8217;s currently supported version of Edge
of 2016, this means IE 11 or IE Edge)
Safari, a release from the current year
the Apple currently supported versions of Safari (as of 2016, this
When accessed from a mobile device, Proxmox VE will show a lightweight, touch-based
means Safari 9)
interface.
If Proxmox VE detects you&#8217;re connecting from a mobile device, you will be
redirected to a lightweight touch-based UI.
</pvehide>
</pvehide>
<!--PVE_IMPORT_END_MARKER-->
<!--PVE_IMPORT_END_MARKER-->

Latest revision as of 14:11, 23 November 2023

We recommend using high quality server hardware, when running Proxmox VE in production. To further decrease the impact of a failed host, you can run Proxmox VE in a cluster with highly available (HA) virtual machines and containers.

Proxmox VE can use local storage (DAS), SAN, NAS, and distributed storage like Ceph RBD. For details see chapter storage.

Minimum Requirements, for Evaluation

These minimum requirements are for evaluation purposes only and should not be used in production.

  • CPU: 64bit (Intel 64 or AMD64)

  • Intel VT/AMD-V capable CPU/motherboard for KVM full virtualization support

  • RAM: 1 GB RAM, plus additional RAM needed for guests

  • Hard drive

  • One network card (NIC)

  • Intel 64 or AMD64 with Intel VT/AMD-V CPU flag.

  • Memory: Minimum 2 GB for the OS and Proxmox VE services, plus designated memory for guests. For Ceph and ZFS, additional memory is required; approximately 1GB of memory for every TB of used storage.

  • Fast and redundant storage, best results are achieved with SSDs.

  • OS storage: Use a hardware RAID with battery protected write cache (“BBU”) or non-RAID with ZFS (optional SSD for ZIL).

  • VM storage:

    • For local storage, use either a hardware RAID with battery backed write cache (BBU) or non-RAID for ZFS and Ceph. Neither ZFS nor Ceph are compatible with a hardware RAID controller.

    • Shared and distributed storage is possible.

    • SSDs with Power-Loss-Protection (PLP) are recommended for good performance. Using consumer SSDs is discouraged.

  • Redundant (Multi-)Gbit NICs, with additional NICs depending on the preferred storage technology and cluster setup.

  • For PCI(e) passthrough the CPU needs to support the VT-d/AMD-d flag.

Simple Performance Overview

To get an overview of the CPU and hard disk performance on an installed Proxmox VE system, run the included pveperf tool.

Note This is just a very quick and general benchmark. More detailed tests are recommended, especially regarding the I/O performance of your system.

Supported Web Browsers for Accessing the Web Interface

To access the web-based user interface, we recommend using one of the following browsers:

  • Firefox, a release from the current year, or the latest Extended Support Release

  • Chrome, a release from the current year

  • Microsoft’s currently supported version of Edge

  • Safari, a release from the current year

When accessed from a mobile device, Proxmox VE will show a lightweight, touch-based interface.