The main purpose of multipath connectivity is to provide redundant access to a storage device, i.e., to have access to the storage device when one or more of the components in a path fail. Another advantage of multipathing is the increased throughput by way of load balancing. | The main purpose of multipath connectivity is to provide redundant access to a storage device, i.e., to have access to the storage device when one or more of the components in a path fail. Another advantage of multipathing is the increased throughput by way of load balancing. |
Revision as of 08:14, 17 October 2024
Note: Article is outdated! Please check out the general article on setting up Multipath. |
Introduction
The main purpose of multipath connectivity is to provide redundant access to a storage device, i.e., to have access to the storage device when one or more of the components in a path fail. Another advantage of multipathing is the increased throughput by way of load balancing. A common example for the use of multipathing is to add redunancy and gain maximum performance from an iSCSI SAN device.
If you use iSCSI, multipath is recommended - this works without configuration on the switches (If you use NFS or CIFS, use bonding, e.g. 802.ad).
The connection from the Proxmox VE host through the iSCSI SAN is referred to as a path. When multiple paths exists to a storage device (LUN) on a storage subsystem, it is referred to as multipath connectivity. Therefore, you need to ensure that you have at least two dedicated NICs for iSCSI, using separate networks (and switches to protect against switch failures).
This is a generic how-to. Please consult the storage vendor documentation for vendor specific settings.
Update your iSCSI configuration
It is important to start all required iSCSI connections at boot time. You can do this by setting 'node.startup' to 'automatic'.
The default 'node.session.timeo.replacement_timeout' is 120 seconds. We recommend using a much smaller value of 15 seconds instead.
You can set those values in '/etc/iscsi/iscsid.conf' (defaults). If you are already connected to the iSCSI target, you need to modify the target specific defaults in '/etc/iscsi/nodes/<TARGET>/<PORTAL>/default'.
A modified 'iscsid.conf' file contains the following lines:
node.startup = automatic node.session.timeo.replacement_timeout = 15
Please configure your iSCSI storage on the GUI if you have not done that already ("Datacenter/Storage: Add iSCSI target").
Activate Multipath
Install multipath tools
The default installation does not include the 'multipath-tools' package, so you first need to install it:
# apt-get update # apt-get install multipath-tools
Configuration
Then you need to create the multipath configuration file '/etc/multipath.conf'. You can find details about each setting in the man page:
# man multipath.conf
We recommend using the 'wwid' (World Wide Identification) to identify disks. You can use the 'scsi_id' command to get the 'wwid' for a specific device. For example, the following command returns the 'wwid' for device '/dev/sda'
# /lib/udev/scsi_id -g -u -d /dev/sda
We normally blacklist all devices, and only allow specific devices using 'blacklist_exceptions':
blacklist { wwid .* } blacklist_exceptions { wwid "3600144f028f88a0000005037a95d0001" wwid "3600144f028f88a0000005037a95d0002" }
We can also use the 'alias' directive to name the device, but this is optional:
multipaths { multipath { wwid "3600144f028f88a0000005037a95d0001" alias mpath0 } multipath { wwid "3600144f028f88a0000005037a95d0002" alias mpath1 } }
Finally, you need reasonable defaults. We normally use the following multibus configuration (PVE 4.x and higher):
defaults { polling_interval 2 path_selector "round-robin 0" path_grouping_policy multibus uid_attribute ID_SERIAL rr_min_io 100 failback immediate no_path_retry queue user_friendly_names yes }
The wwids must also be added to the file '/etc/multipath/wwids'. To do this, run the following commands with the appropriate wwids:
# multipath -a 3600144f028f88a0000005037a95d0001 # multipath -a 3600144f028f88a0000005037a95d0002
You should also check your SAN vendor's documentation for additional information.
To activate these settings, you need to restart the multipath daemon with:
# systemctl restart multipath-tools.service
Prioritizing a Certain TCP/IP Path
If, for example, the path to destination IP address 192.168.99.99 should be prioritized (where other IP routes will be used as failover), the default section should be as follows:
defaults { polling_interval 2 path_selector "round-robin 0" path_grouping_policy failover uid_attribute ID_SERIAL rr_min_io 100 failback immediate prio iet prio_args preferredip=192.168.99.99 no_path_retry queue user_friendly_names yes }
Query device status
You can view the status with:
# multipath -ll
mpath0 (3600144f028f88a0000005037a95d0001) dm-3 NEXENTA,NEXENTASTOR size=64G features='1 queue_if_no_path' hwhandler='0' wp=rw `-+- policy='round-robin 0' prio=2 status=active |- 5:0:0:0 sdb 8:16 active ready running `- 6:0:0:0 sdc 8:32 active ready running
To get more information about used devices use:
# multipath -v3
Performance test with fio
In order to check the performance, you can use fio.
Example read test:
fio --filename=/dev/mapper/mpath0 --direct=1 --rw=read --bs=1m --size=20G --numjobs=200 --runtime=60 --group_reporting --name=file1
Vendor specific settings
Please add vendor specific recommendations here.
Dell
You need to load a Dell specific module scsi_dh_rdac permanently, in order to do this, just edit:
nano /etc/modules
# /etc/modules: kernel modules to load at boot time. # # This file contains the names of kernel modules that should be loaded # at boot time, one per line. Lines beginning with "#" are ignored. # Parameters can be specified after the module name. scsi_dh_rdac
defaults { polling_interval 2 path_selector "round-robin 0" path_grouping_policy multibus getuid_callout "/lib/udev/scsi_id -g -u -d /dev/%n" rr_min_io 100 failback immediate no_path_retry queue } blacklist { wwid * } blacklist_exceptions { wwid 3690b22c00008da2c000008a35098b0dc } devices { device { vendor "DELL" product "MD32xxi" path_grouping_policy group_by_prio prio rdac polling_interval 5 path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 } } multipaths { multipath { wwid 3690b22c00008da2c000008a35098b0dc alias md3200i } }
And you need to configure a suitable filter in /etc/lvm/lvm.conf in order to avoid error messages.
See also:
Reduxio HX550
Configuration
You need to configure the following:
- Update /etc/iscsi/iscsid.conf
- Create/update /etc/multipath.conf
- Create /etc/udev/rules.d/99-reduxio.rules
/etc/iscsi/iscsid.conf
Add or update the following parameters:
node.startup = automatic # The length of time to wait before retrying a failed IO . Can be reduced to a minimum since multipath detects the failure and immediately fails to another path. The value is in seconds and the default is typically 120. node.session.timeo.replacement_timeout = 5 # The time to wait for an iSCSI login to complete. The value is in seconds and the default is 15. node.conn[0].timeo.login_timeout = 15 # To specify the time to wait for logout to complete, edit the line. # The value is in seconds and the default is 15 seconds. node.conn[0].timeo.logout_timeout = 15 # Time interval to wait for on connection before sending a ping. node.conn[0].timeo.noop_out_interval = 5 # To specify the time to wait for a Nop-out response before failing # the connection, edit this line. Failing the connection will # cause IO to be failed back to the SCSI layer. If using dm-multipath # this will cause the IO to be failed to the multipath layer. node.conn[0].timeo.noop_out_timeout = 5 # # This retry count along with node.conn[0].timeo.login_timeout # determines the maximum amount of time iscsid will try to # establish the initial login. node.session.initial_login_retry_max is # multiplied by the node.conn[0].timeo.login_timeout to determine the # maximum amount. node.session.initial_login_retry_max 8
/etc/udev/rules.d/99-reduxio.rules
Create the following file:
# /etc/udev/rules.d/99-reduxio.rules SUBSYSTEM=="block" , ACTION=="change", ATTRS{model}=="TCAS", ATTRS{vendor}=="REDUXIO", RUN+="/bin/sh -c '/usr/sbin/iscsiadm -m session -R '" SUBSYSTEM=="block" , ACTION=="change", ATTRS{model}=="TCAS", ATTRS{vendor}=="REDUXIO", ATTR{size}=="0", RUN+="/bin/sh -c 'echo 1 > /sys$DEVPATH/../../delete '" SUBSYSTEM=="block" , ACTION=="change", ATTRS{model}=="TCAS", ATTRS{vendor}=="REDUXIO", RUN+="/bin/sh -c 'service multipathd reload || service multipath-tools reload ' " SUBSYSTEM=="block" , ACTION=="change", ATTRS{model}=="TCAS", ATTRS{vendor}=="REDUXIO", RUN+="/bin/sh -c '/usr/sbin/multipath -r $DEVNAME '"
/etc/multipath.conf
Create or update /etc/multipath.conf. This is required for correct high-availability
devices { device { vendor "REDUXIO" product "TCAS" revision "2300" path_grouping_policy "group_by_prio" path_checker "tur" hardware_handler "1 alua" path_selector "round-robin 0" prio "alua" failback "immediate" features "0" rr_weight "uniform" no_path_retry "72" queue_without_daemon "no" rr_min_io_rq 10 rr_min_io 10 user_friendly_names "yes" fast_io_fail_tmo "10" } } blacklist { # Note: it is highly recommended to blacklist by wwid or vendor instead of device name devnode "^sd[a]$" }