=Introduction=
+
For details about DRBD with Proxmox VE, please follow the documentation from Linbit, the creators of DRBD and maintainers of the DRBD storage plugin.
DRBD® refers to block devices designed as a building block to form high availability (HA) clusters. This is done by mirroring a whole block device via an assigned network. DRBD can be understood as network based raid-1. For detailed information please visit [http://www.linbit.com Linbit].
 
  
Main features of the integration in Proxmox VE:
+
https://docs.linbit.com/docs/users-guide-9.0/#ch-proxmox
*LVM on top of DRBD (Primary/Primary)
 
*All VM disks (LVM volumes on the DRBD device) are replicated in real time on both Proxmox VE nodes via the network
 
*Ability to live migrate running machines without downtime in a few seconds WITHOUT the need of SAN (iSCSI, FC, NFS) as the data is already on both nodes.
 
  
Note: Currently only KVM guests can use the new [[Storage Model]].
+
[[Category:HOWTO]]
 
 
For this HowTo I used a Intel Entry Server main board with 2 Intel GBit Network cards and two simple SATA hard drives. On /dev/sda I installed Proxmox VE as usual, /dev/sdb/ will be used for DRBD. Eth0 is used for the default VMBR0 and eth1 will be used for DRBD.
 
 
 
=System requirements=
 
You need 2 identical Proxmox VE servers with the following extra hardware:
 
*Free network card (connected with a direct crossover cable)
 
*Second raid volume (e.g. /dev/sdb)
 
*Use a hardware raid controller with BBU to eliminate performance issues concerning internal metadata (see [http://fghaas.wordpress.com/2009/08/20/internal-metadata-and-why-we-recommend-it/ Florian´s blog]).
 
 
 
=Preparations=
 
Make sure you run at least Proxmox VE 1.4 on both servers and create the well known standard [[Proxmox VE Cluster]].
 
 
 
==Network==
 
Configure eth1 on both nodes with a fixed private IP address via the web interface and reboot each server.
 
 
 
For better understanding, here is my /etc/network/interfaces file from my first node after the reboot:
 
 
 
<pre>cat /etc/network/interfaces
 
# network interface settings
 
auto lo
 
iface lo inet loopback
 
 
 
iface eth0 inet manual
 
 
 
auto eth1
 
iface eth1 inet static
 
        address  10.0.7.105
 
        netmask  255.255.240.0
 
 
 
auto vmbr0
 
iface vmbr0 inet static
 
        address  192.168.7.105
 
        netmask  255.255.240.0
 
        gateway  192.168.2.1
 
        bridge_ports eth0
 
        bridge_stp off
 
        bridge_fd 0</pre>
 
 
 
And from the second node:
 
<pre># network interface settings
 
auto lo
 
iface lo inet loopback
 
 
 
iface eth0 inet manual
 
 
 
auto eth1
 
iface eth1 inet static
 
        address  10.0.7.106
 
        netmask  255.255.240.0
 
 
 
auto vmbr0
 
iface vmbr0 inet static
 
        address  192.168.7.106
 
        netmask  255.255.240.0
 
        gateway  192.168.2.1
 
        bridge_ports eth0
 
        bridge_stp off
 
        bridge_fd 0</pre>
 
 
 
==Disk for DRBD==
 
I will use /dev/sdb1 for DRBD. Therefore I need to create this single big partition on /dev/sdb - make sure that this is 100% identical on both nodes.
 
 
 
Just run fdisk /dev/sdb and create a primary partition (dev/sdb1):
 
 
 
<pre>proxmox-105:~# fdisk /dev/sdb
 
                                                                                                                                                           
 
The number of cylinders for this disk is set to 19457.                                                                                                         
 
There is nothing wrong with that, but this is larger than 1024,                                                                                               
 
and could in certain setups cause problems with:                                                                                                               
 
1) software that runs at boot time (e.g., old versions of LILO)                                                                                               
 
2) booting and partitioning software from other OSs                                                                                                           
 
  (e.g., DOS FDISK, OS/2 FDISK)                                                                                                                               
 
                                                                                                                                                               
 
Command (m for help): n                                                                                                                                       
 
Command action                                                                                                                                                 
 
  e  extended                                                                                                                                               
 
  p  primary partition (1-4)                                                                                                                                 
 
p                                                                                                                                                             
 
Partition number (1-4): 1                                                                                                                                     
 
First cylinder (1-19457, default 1):                                                                                                                           
 
Using default value 1                                                                                                                                         
 
Last cylinder or +size or +sizeM or +sizeK (1-19457, default 19457):                                                                                           
 
Using default value 19457                                                                                                                                     
 
                                                                                                                                                               
 
Command (m for help): t                                                                                                                                       
 
Selected partition 1                                                                                                                                           
 
Hex code (type L to list codes): 8e                                                                                                                           
 
Changed system type of partition 1 to 8e (Linux LVM)                                                                                                           
 
                                                                                                                                                               
 
Command (m for help): p                                                                                                                                       
 
                                                                                                                                                               
 
Disk /dev/sdb: 160.0 GB, 160041885696 bytes                                                                                                                   
 
255 heads, 63 sectors/track, 19457 cylinders                                                                                                                   
 
Units = cylinders of 16065 * 512 = 8225280 bytes                                                                                                               
 
Disk identifier: 0x49e2fd2f                                                                                                                                   
 
                                                                                                                                                               
 
  Device Boot      Start        End      Blocks  Id  System                                                                                                 
 
/dev/sdb1              1      19457  156288321  8e  Linux LVM                                                                                             
 
                                                                                                                                                               
 
Command (m for help): w                                                                                                                                       
 
The partition table has been altered!                                                                                                                         
 
                                                                                                                                                               
 
Calling ioctl() to re-read partition table.                                                                                                                   
 
                                                                                         
 
Syncing disks.
 
proxmox-105:~#
 
</pre>
 
 
 
=DRBD configuration=
 
==Software installation==
 
Install the DRBD user tools on both nodes (I got DRBD 8.3.2 in the Kernel and also 8.3.2 drbd8-utils):
 
<pre>apt-get install drbd8-utils</pre>
 
 
 
'''Note:'''
 
It is advisable to have a DRBD userland version that matches the kernel module version.
 
See this forum post for a short build howto:
 
 
 
http://forum.proxmox.com/threads/7059-Update-DRBD-userland-to-8.3.10-to-match-kernel-in-1.9?p=40033#poststop
 
 
 
==Prepare drbd.conf file==
 
Edit the drbd config file, please note that this file needs to be identical on both nodes, here is an example:
 
<pre>proxmox-105:~# cat /etc/drbd.conf
 
global { usage-count no; }
 
common { syncer { rate 30M; } }
 
resource r0 {
 
        protocol C;
 
        startup {
 
                wfc-timeout  15;    # wfc-timeout can be dangerous (http://forum.proxmox.com/threads/3465-Is-it-safe-to-use-wfc-timeout-in-DRBD-configuration)
 
                degr-wfc-timeout 60;
 
                become-primary-on both;
 
        }
 
        net {
 
                cram-hmac-alg sha1;
 
                shared-secret "my-secret";
 
                allow-two-primaries;
 
                after-sb-0pri discard-zero-changes;
 
                after-sb-1pri discard-secondary;
 
                after-sb-2pri disconnect;
 
        }
 
        on proxmox-105 {
 
                device /dev/drbd0;
 
                disk /dev/sdb1;
 
                address 10.0.7.105:7788;
 
                meta-disk internal;
 
        }
 
        on proxmox-106 {
 
                device /dev/drbd0;
 
                disk /dev/sdb1;
 
                address 10.0.7.106:7788;
 
                meta-disk internal;
 
        }
 
}
 
</pre>
 
 
 
==Start DRBD==
 
On both servers, start DRBD:
 
 
 
<pre>/etc/init.d/drbd start</pre>
 
 
 
now create the device metadata, also on both nodes:
 
 
 
<pre>drbdadm create-md r0</pre>
 
 
 
Bring the device up, also on both nodes:
 
<pre>drbdadm up r0</pre>
 
 
 
Now you can take on current status of the DRBD, should look like this on both nodes:
 
<pre>proxmox-105:~# cat /proc/drbd
 
version: 8.3.2 (api:88/proto:86-90)
 
GIT-hash: dd7985327f146f33b86d4bff5ca8c94234ce840e build by root@oahu, 2009-09-10 15:18:39
 
0: cs:Connected ro:Secondary/Secondary ds:Inconsistent/Inconsistent C r----
 
    ns:0 nr:0 dw:0 dr:0 al:0 bm:0 lo:0 pe:0 ua:0 ap:0 ep:1 wo:b oos:2096348
 
</pre>
 
 
 
Now DRBD has successfully allocated resources and is ready for operation. Now start the initial synchronization (only on one node!!!):
 
 
 
<pre>drbdadm -- --overwrite-data-of-peer primary r0</pre>
 
 
 
Wait till the initial sync is finished (depending on the size and speed this process can take some time):
 
<pre>proxmox-120:~# watch cat /proc/drbd</pre>
 
 
 
Finally check if your DRBD is starting in Primary/Primary mode. In order to do this, just stop DRBD service on both nodes:
 
 
 
<pre>/etc/init.d/drbd stop</pre>
 
 
 
And start again on both nodes:
 
<pre>/etc/init.d/drbd start</pre>
 
 
 
Now DRBD should be in the Primary/Primary mode:
 
<pre>proxmox-105:~# cat /proc/drbd
 
version: 8.3.2 (api:88/proto:86-90)
 
GIT-hash: dd7985327f146f33b86d4bff5ca8c94234ce840e build by root@oahu, 2009-09-10 15:18:39
 
0: cs:Connected ro:Primary/Primary ds:UpToDate/UpToDate C r----
 
    ns:0 nr:0 dw:0 dr:268 al:0 bm:0 lo:0 pe:0 ua:0 ap:0 ep:1 wo:b oos:0
 
</pre>
 
 
 
==LVM configuration==
 
Now we got a running /dev/drbd0 in Primary/Primary mode and we need to add LVM on top of this device.
 
===Adapt your lvm.conf===
 
You need to change the filter section in the LVM configuration, just edit the corresponding line in lvm.conf - do this on both nodes:
 
 
 
<pre>nano /etc/lvm/lvm.conf
 
 
 
# By default we accept every block device:
 
filter = [ "r|/dev/sdb1|", "r|/dev/disk/|", "r|/dev/block/|", "a/.*/" ]
 
</pre>
 
 
 
Note: if you device is not /dev/sdb change this according to our system
 
===Create the physical volume for LVM===
 
On one node, create the physical volume:
 
<pre>proxmox-105:~# pvcreate /dev/drbd0
 
  Physical volume "/dev/drbd0" successfully created
 
proxmox-105:~#</pre>
 
 
 
Check your physical volumes, should look like this:
 
<pre>proxmox-105:~# pvscan
 
  PV /dev/sda2    VG pve            lvm2 [465.26 GB / 4.00 GB free]
 
  PV /dev/drbd0                      lvm2 [149.04 GB]
 
  Total: 2 [613.30 GB] / in use: 1 [613.30 GB] / in no VG: 1 [4.00 GB]
 
proxmox-105:~#</pre>
 
 
 
===Create the volume group===
 
On one node, create the volume group:
 
<pre>proxmox-105:~# vgcreate drbdvg /dev/drbd0
 
  Volume group "drbdvg" successfully created
 
proxmox-105:~#
 
</pre>
 
 
 
Check your physical volumes again, should look like this:
 
<pre>proxmox-105:~# pvscan
 
  PV /dev/sda2    VG pve            lvm2 [465.26 GB / 4.00 GB free]
 
  PV /dev/drbd0  VG drbdvg          lvm2 [149.04 GB / 149.04 GB free]
 
...
 
proxmox-105:~#</pre>
 
 
 
===Add the LVM group to the Proxmox VE storage list via web interface===
 
Go to the Proxmox VE web interface to 'Configuration/Storage' and click on the red arrow and select 'Add LVM group'.
 
 
 
You will see the previously created volume group (drbdvg), select this and give a Storage Name (cannot be changed later, so think twice), and enable the sharing by click the 'shared' box.
 
 
 
=Create the first VM on DRBD for testing and live migration=
 
In order to check end to end functionality, create a new KVM VM - and obviously store the VM disk on the previously created storage. Now, if you install the operating system - in my case a Ubuntu 9.04 all the data is already replicated automatically on both nodes - just finish the installation and reboot into your VM.
 
 
 
Try to live migrate the VM - as all data is available on both nodes it just take a few seconds. The overall process can take a bit longer if the VM is under load and if there is a lot of RAM involved. But in any case, the downtime is minimal and you will see no interruption at all - like you use iSCSI or NFS for storage back-end.
 
 
 
=DRBD suppport=
 
DRBD can be configured in many ways and there is a lot of space for optimizations and performance tuning. If you run DRBD in a production environment we highly recommend the [http://www.linbit.com/en/products-services/drbd-support/drbd-support/ 24/7 support packages] from the DRBD developers. The company behind DRBD is [http://www.linbit.com Linbit], they just live a few miles away from the Proxmox headquarter, so this makes it easy to cooperate.
 
 
 
=Recovery from communication failure=
 
When the communication channel between the two DRBD nodes fails (commonly known as a "split-brain" situation), both nodes continue independently. When the communication channel is re-established the two nodes will no longer have the same data in their DRBD volumes, and re-synchronisation is required.
 
 
 
In the dual-primary configuration used with Proxmox VE, both nodes may have changes to the same DRBD resource that have occurred since the split-brain condition. In this case it will be necessary to discard the data of one of the nodes. Normally one would choose to discard the data of the least-active node.
 
 
 
Virtual disk data on that node can be preserved by using the PVE web interface to migrate those virtual machines on to the node which will have its data preserved. This does mean that these virtual machines will need to be taken out of service while their complete virtual disk data is copied to the other node.
 
 
 
It is therefore advisable to always run "mission critical" VMs on one of the nodes, and use its peer for "development" VMs. Alternatively it is possible to create two DRBD volumes and use one for VMs that normally run on node A, and the other for VMs that are normally on B. Thus little or no forced migration is needed after a split-brain condition.
 
 
 
For specific recovery steps, see [http://www.drbd.org/users-guide-emb/s-resolve-split-brain.html DRBD's documentation on resolving split-brain conditions].
 
 
 
=Final considerations=
 
Now you have a fully redundant storage for your VM´s with just no need of expensive SAN equipment, configured in about 30 to 60 minutes - starting from bare-metal. If you want to achieve a similar setup with traditional virtualization solutions with SAN you will need at least 4 servers boxes and the storage network.
 
 
 
'''Traditional setup with SAN (eg. iSCSI, NFS, FC):'''
 
*Two servers for a redundant SAN
 
*Two servers for redundant virtualization hosts
 
*Extra storage network, VLAN´s, FC switches, etc
 
*Complex setup
 
 
 
'''Proxmox VE with DRBD:'''
 
*Only two servers with raid controllers and a bunch of hard drives (configure two raid volumes, one for Proxmox VE and one for DRBD device)
 
 
 
Beginning with Kernel 2.6.33, DRBD is integrated into the mainline Kernel (also most 2.6.32 Kernels got it backported). This makes it much easier to maintain and upgrade the systems and can be considered as the "highest quality certificate" for Kernel module developers.
 
 
 
Additionally, DRBD will be the base for high availability (HA) - please help by testing, reporting bugs and issues in our forum or mailing list.
 
 
 
[[Category: HOWTO]] [[Category: Technology]]
 

Latest revision as of 15:52, 15 May 2018

For details about DRBD with Proxmox VE, please follow the documentation from Linbit, the creators of DRBD and maintainers of the DRBD storage plugin.

https://docs.linbit.com/docs/users-guide-9.0/#ch-proxmox