Difference between revisions of "ISCSI Multipath"

From Proxmox VE
Jump to navigation Jump to search
Line 87: Line 87:
 
</pre>
 
</pre>
  
'''Note''' If you run multipath on V3.0 and later, you need to adapt your multipath.conf - 'selector' is now called 'path_selector'  
+
'''Note''' If you run multipath on V2.3 and before, you need to adapt your multipath.conf - 'path_selector' was called 'selector' called 
  
 
Also check your SAN vendor documentation.
 
Also check your SAN vendor documentation.

Revision as of 08:50, 16 July 2013

Introduction

Main purpose of multipath connectivity is to provide redundant access to the storage devices, i.e to have access to the storage device when one or more of the components in a path fail. Another advantage of multipathing is the increased throughput by way of load balancing. Common example for the use of multipathing is a iSCSI SAN connected storage device. You have redundancy and maximum performance.

If you use iSCSI, multipath is recommended - this works without configurations on the switches. (If you use NFS or CIFS, use bonding, e.g. 802.ad)

The connection from the Proxmox VE host through the iSCSI SAN is referred as a path. When multiple paths exists to a storage device (LUN) on a storage subsystem, it is referred as multipath connectivity. Therefore you need to make sure that you got at least two NICs dedicated for iSCSI, using separate networks (and switches to be protected against switch failures).

This is a generic how-to. Please consult the storage vendor documentation for vendor specific settings.

Update your iSCSI configuration

It is important to start all required iSCSI connections at boot time. You can do that by setting 'node.startup' to 'automatic'.

The default 'node.session.timeo.replacement_timeout' is 120 seconds. We recommend using a much smaller value of 15 seconds instead.

You can set those values in '/etc/iscsi/iscsid.conf' (defaults). If you are already connected to the iSCSI target, you need to modify the target specific defaults in '/etc/iscsi/nodes/<TARGET>/<PORTAL>/default'

A modified 'iscsid.conf' file contains the following lines:

node.startup = automatic
node.session.timeo.replacement_timeout = 15

Please configure your iSCSI storage on the GUI if you have not done that already ("Datacenter/Storage: Add iSCSI target").

Install multipath tools

The default installation does not include this package, so you first need to install the multipath-tools package:

# aptitude update
# aptitude install multipath-tools

Multipath configuration

Then you need to create the multipath configuration file '/etc/multipath.conf'. You can find details about all setting on the manual page:

# man multipath.conf

We recommend to use 'wwid' to identify disks (World Wide Identification). You can use the 'scsi_id' command to get the 'wwid' for a specific device. For example, the following command returns the 'wwid' for device '/dev/sda'

# /lib/udev/scsi_id -g -u -d /dev/sda

We normally blacklist all devices, and only allow specific devices using 'blacklist_exceptions':

blacklist {
        wwid *
}

blacklist_exceptions {
        wwid "3600144f028f88a0000005037a95d0001"
        wwid "3600144f028f88a0000005037a95d0002"
}

We also use the 'alias' directive to name the device, but this is optional:

multipaths {
  multipath {
        wwid "3600144f028f88a0000005037a95d0001"
        alias mpath0
  }
  multipath {
        wwid "3600144f028f88a0000005037a95d0002"
        alias mpath1
  }
}

And finally you need reasonable defaults. We normally use the following multibus configuration:

defaults {
        polling_interval        2
        path_selector           "round-robin 0"
        path_grouping_policy    multibus
        getuid_callout          "/lib/udev/scsi_id -g -u -d /dev/%n"
        rr_min_io               100
        failback                immediate
        no_path_retry           queue
}

Note If you run multipath on V2.3 and before, you need to adapt your multipath.conf - 'path_selector' was called 'selector' called

Also check your SAN vendor documentation.

To activate those settings you need to restart they multipath daemon with:

# service multipath-tools restart

Example multipath.conf

# cat /etc/mulitpath.conf
defaults {
        polling_interval        2
        patch_selector                "round-robin 0"
        path_grouping_policy    multibus
        getuid_callout          "/lib/udev/scsi_id -g -u -d /dev/%n"
        rr_min_io               100
        failback                immediate
        no_path_retry           queue
}
blacklist {
        wwid *
}

blacklist_exceptions {
        wwid "3600144f028f88a0000005037a95d0001"
}

multipaths {
  multipath {
        wwid "3600144f028f88a0000005037a95d0001"
        alias nexenta0
  }
}

Query device status

You can view the status with:

# multipath -ll
mpath0 (3600144f028f88a0000005037a95d0001) dm-3 NEXENTA,NEXENTASTOR
size=64G features='1 queue_if_no_path' hwhandler='0' wp=rw
`-+- policy='round-robin 0' prio=2 status=active
  |- 5:0:0:0 sdb 8:16 active ready running
  `- 6:0:0:0 sdc 8:32 active ready running


To get more information about used devices use:

# multipath -v3


Performance test with fio

In order to check the performance, you can use fio.

Example read test:

fio --filename=/dev/mapper/mpath0 --direct=1 --rw=read --bs=1m --size=20G --numjobs=200 --runtime=60 --group_reporting --name=file1

Vendor specific settings

Please add vendor specific recommendations here.

Dell

You need to load a Dell specific module scsi_dh_rdac permanently, in order to do this, just edit:

nano /etc/modules
# /etc/modules: kernel modules to load at boot time.
#
# This file contains the names of kernel modules that should be loaded
# at boot time, one per line. Lines beginning with "#" are ignored.
# Parameters can be specified after the module name.
scsi_dh_rdac


defaults {
        polling_interval        2
        selector                "round-robin 0"
        path_grouping_policy    multibus
        getuid_callout          "/lib/udev/scsi_id -g -u -d /dev/%n"
        rr_min_io               100
        failback                immediate
        no_path_retry           queue
}
blacklist {
        wwid *
}

blacklist_exceptions {
        wwid 3690b22c00008da2c000008a35098b0dc
        
}

devices {
        device {
                vendor                  "DELL"
                product                 "MD32xxi"
                path_grouping_policy    group_by_prio
                prio                    rdac
                polling_interval        5
                path_checker            rdac
                path_selector           "round-robin 0"
                hardware_handler        "1 rdac"
                failback                immediate
                features                "2 pg_init_retries 50"
                no_path_retry           30
                rr_min_io               100
        }
}

multipaths {
        multipath {
                wwid 3690b22c00008da2c000008a35098b0dc
                alias md3200i
        }
        
}

And you need to configure a suitable filter in /etc/lvm/lvm.conf in order to avoid error messages.

See also:

External links