Difference between revisions of "Performance Tweaks"

From Proxmox VE
Jump to navigation Jump to search
(→‎Disk Cache: add image for each cache mode)
 
(27 intermediate revisions by 9 users not shown)
Line 1: Line 1:
{{Note|Article about Proxmox VE 2.0}}
+
=Introduction=
 +
This page is intended to be a collection of various performance tips/tweaks to help you get the most from your KVM virtual machines.
 +
 
 +
= General =
 +
 
 +
=== VirtIO ===
 +
Use virtIO for disk and network for best performance.
 +
* Linux has the drivers built in since Linux 2.6.24 as experimental, and since Linux 3.8 as stable
 +
* [http://freebsd.org FreeBSD] has the drivers built in since 9.0
 +
* Windows requires the [[Windows VirtIO Drivers]] to be downloaded and  installed manually
 +
 
 +
===Disk Cache===
 +
{{Note|The information below is based on using raw volumes, other volume formats may behave differently.}}
  
 +
====Small Overview====
  
[[Category: Proxmox VE 2.0]]
+
Note: The overview below is dependent of the specific hardware used, for example a HW Raid with a BBU backed disk cache works just fine with 'writeback' mode, so take it just as an general overview.
=Introduction=
+
 
This page is intended to be a collection of various performance tips/tweaks to help you get the most from your virtual servers.
+
{| class="wikitable sortable"
=KVM=
+
|-
==USB Tablet Device==
+
! Mode !! Host Page Cache !! Disk Write Cache !! Notes
Disabling the USB tablet device in windows VMs can reduce idle CPU usage and reduce context switches.
+
|-
[http://forum.proxmox.com/threads/9981-disable-quot-usbdevice-tablet-quot-for-all-VM]
+
| none || disabled || enabled || balances performance and safety (better writes)
 +
|-
 +
| writethrough || enabled || disabled || balances performance and safety (better reads)
 +
|-
 +
| writeback || enabled || enabled || fast, can loose data on power outage depending on hardware used
 +
|-
 +
| directsync || disabled || disabled || safest but slowest (relative to the others)
 +
|-
 +
| unsafe || enabled || enabled || doesn't flush data, fastest and unsafest
 +
|}
 +
[[File:Cache mode none.png|150px|border|right]]
 +
'''cache=none''' seems to be the best performance and is the default since Proxmox 2.X.
 +
 
 +
* host page cache is not used
 +
* guest disk cache is set to writeback
 +
* Warning: like writeback, you can lose data in case of a power failure
 +
* You need to use the barrier option in your Linux guest's fstab if kernel < 2.6.37 to avoid FS corruption in case of power failure.
  
==VirtIO==
+
<blockquote>
Use virtIO for disk and network for best performance.
+
This mode causes qemu-kvm to interact with the disk image file or block device with O_DIRECT semantics, so the host page cache is bypassed and I/O happens directly between the qemu-kvm userspace buffers and the storage device. Because the actual storage device may report a write as completed when placed in its write queue only, the guest's virtual storage adapter is informed that there is a writeback cache, so the guest would be expected to send down flush commands as needed to manage data integrity. Equivalent to direct access to your hosts' disk, performance wise.
 +
</blockquote>
  
Linux has the drivers built in
+
<br clear=all>
 +
[[File:Cache mode writethrough.png|150px|border|right]]
 +
'''cache=writethrough'''
 +
* host page cache is used as read cache
 +
* guest disk cache mode is writethrough
 +
* Writethrough causes an fsync for each write. It's the more secure cache mode, you can't lose data but it is also slower.
  
Windows requires drivers which can be obtained here: [http://alt.fedoraproject.org/pub/alt/virtio-win/latest/images/bin/ Fedora VirtIO Drivers]
+
<blockquote>
 +
This mode causes qemu-kvm to interact with the disk image file or block device with O_DSYNC semantics, where writes are reported as completed only when the data has been committed to the storage device. The host page cache is used in what can be termed a writethrough caching mode. Guest virtual storage adapter is informed that there is no writeback cache, so the guest would not need to send down flush commands to manage data integrity. The storage behaves as if there is a writethrough cache.
 +
</blockquote>
  
==Disk Cache==
+
<br clear=all>
{{Note|The information below is based on using raw volumes, other volume formats may behave differently.}}
+
[[File:Cache mode direct.png|150px|border|right]]
 +
'''cache=directsync'''
 +
* host page cache is not used
 +
* guest disk cache mode is writethrough
 +
* similar to writethrough, an fsync is made for each write.
  
cache=none seems to be the best performance and is the default in Proxmox 2.X.
+
<blockquote>
      host don't do cache.  
+
This mode causes qemu-kvm to interact with the disk image file or block device with both O_DSYNC and O_DIRECT semantics, where writes are reported as completed only when the data has been committed to the storage device, and when it is also desirable to bypass the host page cache. Like cache=writethrough, it is helpful to guests that do not send flushes when needed. It was the last cache mode added, completing the possible combinations of caching and direct access semantics.
      guest disk cache is writeback
+
</blockquote>
      Warn : like writeback, you can loose datas in case of a powerfailure
 
      you need to use barrier option in your linux guest fstab if kernel < 2.6.37 to avoid fs corruption in case of powerfailure.     
 
     
 
cache=writethrough
 
      host do read cache
 
      guest disk cache mode is writethrough
 
      Writethrough make a fsync for each write. So it's the more secure cache mode, you can't loose data. It's also the slower.
 
   
 
  
cache=directsync.
+
<br clear=all>
      host don't do cache.
+
[[File:Cache mode writeback.png|150px|border|right]]
      guest disk cache mode is writethrough
+
'''cache=writeback'''
      similar to writethrough, a fsync is made for each write.
+
* host page cache is used as read & write cache
   
+
* guest disk cache mode is writeback
 +
* Warning: you can lose data in case of a power failure
 +
* You need to use the barrier option in your Linux guest's fstab if kernel < 2.6.37 to avoid FS corruption in case of power failure.
  
cache=writeback
+
<blockquote>
      host do read/write cache
+
This mode causes qemu-kvm to interact with the disk image file or block device with neither O_DSYNC nor O_DIRECT semantics, so the host page cache is used and writes are reported to the guest as completed when placed in the host page cache, and the normal page cache management will handle commitment to the storage device. Additionally, the guest's virtual storage adapter is informed of the writeback cache, so the guest would be expected to send down flush commands as needed to manage data integrity. Analogous to a raid controller with RAM cache.
      guest disk cache mode is writeback
+
</blockquote>
      Warn : you can loose datas in case of a powerfailure
 
      you need to use barrier option in your linux guest fstab if kernel < 2.6.37 to avoid fs corruption in case of powerfailure.
 
     
 
  
caching adds additional data copies and bus traffic causing it to perform worse.
+
'''cache=writeback (unsafe)'''
 +
* as '''writeback''', but ignores flush commands from the guest!
 +
* Warning: No data integrity even if the guest is sending flush commands. Not recommended for production use.
 +
----
  
 
For read cache memory: try to add more memory in your guest, they already do the job with their buffer cache
 
For read cache memory: try to add more memory in your guest, they already do the job with their buffer cache
  
cache=directsync and writethrough can be fast, if you have a san or raid controller with cache with battery by exemple
+
cache=writethrough or directsync can be also quite fast if you have a SAN or HW raid controller with battery backed cache.
  
Avoid to use cache=directsync and writethrough with qcow2 files.
+
Using qcow2 backed disks and either cache=directsync or writethrough can make things slower.
  
  
 
some interestings articles :
 
some interestings articles :
  
barriers : http://monolight.cc/2011/06/barriers-caches-filesystems/
+
cache mode and fsync : http://www.ilsistemista.net/index.php/virtualization/23-kvm-storage-performance-and-cache-settings-on-red-hat-enterprise-linux-62.html?start=2
  
cache mode and fsync : http://www.ilsistemista.net/index.php/virtualization/23-kvm-storage-performance-and-cache-settings-on-red-hat-enterprise-linux-62.html?start=2
+
=OS Specific =
 +
== Windows ==
 +
 
 +
=== USB Tablet Device ===
 +
Disabling the USB tablet device in windows VMs can reduce idle CPU usage and reduce context switches. This can be done on the GUI. You can use vmmouse to get the pointer in sync (load drivers inside your VM).
 +
[http://forum.proxmox.com/threads/9981-disable-quot-usbdevice-tablet-quot-for-all-VM]
 +
 
 +
=== Use raw disk image and not qcow2 ===
 +
 
 +
Consider using raw image or partition for a partition, especially  with Microsoft SQL database files because qcow2 can be very slow under such type of load.
  
=Application Specific Tweaks=
+
=== Trace Flag T8038 with Microsoft SQL Server ===
==Microsoft SQL Server==
 
===Trace Flag T8038===
 
 
Setting the trace flag -T8038 will drastically reduce the number of context switches when running SQL 2005 or 2008.
 
Setting the trace flag -T8038 will drastically reduce the number of context switches when running SQL 2005 or 2008.
  
Line 73: Line 115:
 
For additional references see: [http://forum.proxmox.com/threads/5770-Windows-guest-high-context-switch-rate-when-idle Proxmox forum]
 
For additional references see: [http://forum.proxmox.com/threads/5770-Windows-guest-high-context-switch-rate-when-idle Proxmox forum]
  
=VZdump=
+
=== Do not use the Virtio Balloon Driver ===
By default vzdump limited to 10000 Kbps (10 Mbps). That's why some user confuse with the slower data transfer on Proxmox. To increase the VZdump speed you need to edit:
+
The Balloon driver has been a source of performance problems on Windows, you should avoid it.
# nano /etc/vzdump.conf
+
(see http://forum.proxmox.com/threads/20265-SOLVED-Hyper-Threading-vs-No-Hyper-Threading-Fixed-vs-Variable-Memory for the discussion thread)
Find out:
 
#bwlimit: KBPS
 
bwlimit: 10000
 
 
 
Change to any value you like.
 

Latest revision as of 08:44, 30 August 2022

Introduction

This page is intended to be a collection of various performance tips/tweaks to help you get the most from your KVM virtual machines.

General

VirtIO

Use virtIO for disk and network for best performance.

  • Linux has the drivers built in since Linux 2.6.24 as experimental, and since Linux 3.8 as stable
  • FreeBSD has the drivers built in since 9.0
  • Windows requires the Windows VirtIO Drivers to be downloaded and installed manually

Disk Cache

Yellowpin.svg Note: The information below is based on using raw volumes, other volume formats may behave differently.

Small Overview

Note: The overview below is dependent of the specific hardware used, for example a HW Raid with a BBU backed disk cache works just fine with 'writeback' mode, so take it just as an general overview.

Mode Host Page Cache Disk Write Cache Notes
none disabled enabled balances performance and safety (better writes)
writethrough enabled disabled balances performance and safety (better reads)
writeback enabled enabled fast, can loose data on power outage depending on hardware used
directsync disabled disabled safest but slowest (relative to the others)
unsafe enabled enabled doesn't flush data, fastest and unsafest
Cache mode none.png

cache=none seems to be the best performance and is the default since Proxmox 2.X.

  • host page cache is not used
  • guest disk cache is set to writeback
  • Warning: like writeback, you can lose data in case of a power failure
  • You need to use the barrier option in your Linux guest's fstab if kernel < 2.6.37 to avoid FS corruption in case of power failure.

This mode causes qemu-kvm to interact with the disk image file or block device with O_DIRECT semantics, so the host page cache is bypassed and I/O happens directly between the qemu-kvm userspace buffers and the storage device. Because the actual storage device may report a write as completed when placed in its write queue only, the guest's virtual storage adapter is informed that there is a writeback cache, so the guest would be expected to send down flush commands as needed to manage data integrity. Equivalent to direct access to your hosts' disk, performance wise.


Cache mode writethrough.png

cache=writethrough

  • host page cache is used as read cache
  • guest disk cache mode is writethrough
  • Writethrough causes an fsync for each write. It's the more secure cache mode, you can't lose data but it is also slower.

This mode causes qemu-kvm to interact with the disk image file or block device with O_DSYNC semantics, where writes are reported as completed only when the data has been committed to the storage device. The host page cache is used in what can be termed a writethrough caching mode. Guest virtual storage adapter is informed that there is no writeback cache, so the guest would not need to send down flush commands to manage data integrity. The storage behaves as if there is a writethrough cache.


Cache mode direct.png

cache=directsync

  • host page cache is not used
  • guest disk cache mode is writethrough
  • similar to writethrough, an fsync is made for each write.

This mode causes qemu-kvm to interact with the disk image file or block device with both O_DSYNC and O_DIRECT semantics, where writes are reported as completed only when the data has been committed to the storage device, and when it is also desirable to bypass the host page cache. Like cache=writethrough, it is helpful to guests that do not send flushes when needed. It was the last cache mode added, completing the possible combinations of caching and direct access semantics.


Cache mode writeback.png

cache=writeback

  • host page cache is used as read & write cache
  • guest disk cache mode is writeback
  • Warning: you can lose data in case of a power failure
  • You need to use the barrier option in your Linux guest's fstab if kernel < 2.6.37 to avoid FS corruption in case of power failure.

This mode causes qemu-kvm to interact with the disk image file or block device with neither O_DSYNC nor O_DIRECT semantics, so the host page cache is used and writes are reported to the guest as completed when placed in the host page cache, and the normal page cache management will handle commitment to the storage device. Additionally, the guest's virtual storage adapter is informed of the writeback cache, so the guest would be expected to send down flush commands as needed to manage data integrity. Analogous to a raid controller with RAM cache.

cache=writeback (unsafe)

  • as writeback, but ignores flush commands from the guest!
  • Warning: No data integrity even if the guest is sending flush commands. Not recommended for production use.

For read cache memory: try to add more memory in your guest, they already do the job with their buffer cache

cache=writethrough or directsync can be also quite fast if you have a SAN or HW raid controller with battery backed cache.

Using qcow2 backed disks and either cache=directsync or writethrough can make things slower.


some interestings articles :

cache mode and fsync : http://www.ilsistemista.net/index.php/virtualization/23-kvm-storage-performance-and-cache-settings-on-red-hat-enterprise-linux-62.html?start=2

OS Specific

Windows

USB Tablet Device

Disabling the USB tablet device in windows VMs can reduce idle CPU usage and reduce context switches. This can be done on the GUI. You can use vmmouse to get the pointer in sync (load drivers inside your VM). [1]

Use raw disk image and not qcow2

Consider using raw image or partition for a partition, especially with Microsoft SQL database files because qcow2 can be very slow under such type of load.

Trace Flag T8038 with Microsoft SQL Server

Setting the trace flag -T8038 will drastically reduce the number of context switches when running SQL 2005 or 2008.

To change the trace flag:

  1. Open the SQL server Configuration Manager
  2. Open the properties for the SQL service typically named MSSQLSERVER
  3. Go to the advanced tab
  4. Append ;-T8038 to the end of the startup parameters option

For additional references see: Proxmox forum

Do not use the Virtio Balloon Driver

The Balloon driver has been a source of performance problems on Windows, you should avoid it. (see http://forum.proxmox.com/threads/20265-SOLVED-Hyper-Threading-vs-No-Hyper-Threading-Fixed-vs-Variable-Memory for the discussion thread)